IEC 61347-2-7:2011

IEC 61347-2-7:2011

December 2011
International standard Current

Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)

IEC 61347-2-7:2011 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598-2-22. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. Significant changes introduced into this third edition include:- modification of IEC 61347-2-7 to become a standard exclusively for d.c. battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-3 Annex J is intended to cover centrally supplied emergency controlgear;- update of Clause 22 - Recharging devices;- modification of Clause 20 battery voltage characterisation to support EBLF measurement. This to simplify and increase reproducibility of testing;- rationalisation of requirements between IEC 61347-2-7 and IEC 60598-2-22 requirements of IEC 60598-2-22 being transferred to IEC 61347-2-7.This publication is to be read in conjunction with IEC 61347-1:2007.

Main informations

Collections

International IEC standards

Publication date

December 2011

Number of pages

70 p.

Reference

IEC 61347-2-7:2011
Sumary
Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)

IEC 61347-2-7:2011 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598-2-22. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. Significant changes introduced into this third edition include:
- modification of IEC 61347-2-7 to become a standard exclusively for d.c. battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-3 Annex J is intended to cover centrally supplied emergency controlgear;
- update of Clause 22 - Recharging devices;
- modification of Clause 20 battery voltage characterisation to support EBLF measurement. This to simplify and increase reproducibility of testing;
- rationalisation of requirements between IEC 61347-2-7 and IEC 60598-2-22 requirements of IEC 60598-2-22 being transferred to IEC 61347-2-7.

This publication is to be read in conjunction with IEC 61347-1:2007.
Replaced standards (1)
IEC 61347-2-7:2006
August 2006
International standard Cancelled
Lamp controlgear - Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency lighting

This part of IEC 61347 specifies particular safety requirements for d.c. supplied electronic ballasts for maintained and non-maintained emergency lighting purposes. It includes specific requirements for ballasts and control units for luminaires for emergency lighting as specified by IEC 60598-2-22.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo