IEC 61439-1:2020

IEC 61439-1:2020

May 2020
International standard Current

Low-voltage switchgear and controlgear assemblies - Part 1: General rules

IEC 61439-1:2020 lays down the general definitions and service conditions, construction requirements, technical characteristics and verification requirements for low-voltage switchgear and controlgear assemblies. NOTE Throughout this document, the term assembly(s) (see 3.1.1) is used for a low-voltage switchgear and controlgear assembly(s). For the purpose of determining assembly conformity, the requirements of the relevant part of the IEC 61439 series, Part 2 onwards, apply together with the cited requirements of this document. For assemblies not covered by Part 3 onward, Part 2 applies. This third edition cancels and replaces the second edition published in 2011. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:a) clarification that power electric converter systems, switch mode power supplies, uninterruptable power supplies and adjustable speed power drive systems are tested to their particular products standard, but when they are incorporated in assemblies the incorporation is in accordance with the IEC 61439 series of standards;b) introduction of a group rated current for circuits within a loaded assembly and the refocusing of temperature-rise verification on this new characteristic;c) addition of requirements in respect of DC;d) introduction of the concept of class I and class II assemblies regarding protection against electric shock.The contents of the corrigendum 1 of December 2021 and corrigendum 2 of September 2023 have been included in this copy.

Main informations

Collections

International IEC standards

Publication date

May 2020

Number of pages

321 p.

Reference

IEC 61439-1:2020
Sumary
Low-voltage switchgear and controlgear assemblies - Part 1: General rules

IEC 61439-1:2020 lays down the general definitions and service conditions, construction requirements, technical characteristics and verification requirements for low-voltage switchgear and controlgear assemblies. NOTE Throughout this document, the term assembly(s) (see 3.1.1) is used for a low-voltage switchgear and controlgear assembly(s). For the purpose of determining assembly conformity, the requirements of the relevant part of the IEC 61439 series, Part 2 onwards, apply together with the cited requirements of this document. For assemblies not covered by Part 3 onward, Part 2 applies. This third edition cancels and replaces the second edition published in 2011. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) clarification that power electric converter systems, switch mode power supplies, uninterruptable power supplies and adjustable speed power drive systems are tested to their particular products standard, but when they are incorporated in assemblies the incorporation is in accordance with the IEC 61439 series of standards;
b) introduction of a group rated current for circuits within a loaded assembly and the refocusing of temperature-rise verification on this new characteristic;
c) addition of requirements in respect of DC;
d) introduction of the concept of class I and class II assemblies regarding protection against electric shock.
The contents of the corrigendum 1 of December 2021 and corrigendum 2 of September 2023 have been included in this copy.
Replaced standards (1)
IEC 61439-1:2011
August 2011
International standard Cancelled
Low-voltage switchgear and controlgear assemblies - Part 1: General rules

IEC 61439-1:2011 lays down the definitions and states the service conditions, construction requirements, technical characteristics and verification requirements for low-voltage switchgear and controlgear assemblies. This standard cannot be used alone to specify an ASSEMBLY or used for a purpose of determining conformity. ASSEMBLIES shall comply with the relevant part of the IEC 61439 series; Parts 2 onwards. This standard applies to low-voltage switchgear and controlgear assemblies (ASSEMBLIES) only when required by the relevant ASSEMBLY standard as follows: - ASSEMBLIES for which the rated voltage does not exceed 1 000 V in case of a.c. or 1 500 V in case of d.c.; - stationary or movable ASSEMBLIES with or without enclosure; - ASSEMBLIES intended for use in connection with the generation, transmission, distribution and conversion of electric energy, and for the control of electric energy consuming equipment; - ASSEMBLIES designed for use under special service conditions, for example in ships and in rail vehicles provided that the other relevant specific requirements are complied with; - ASSEMBLIES designed for electrical equipment of machines provided that the other relevant specific requirements are complied with. This second edition cancels and replaces the first edition published in 2009. It constitutes a technical revision. This second edition includes the following significant technical changes with respect to the last edition of IEC 61439-1: - revision of service conditions in Clause 7; - numerous changes regarding verification methods in Clause 10; - modification of routine verification in respect of clearances and creepage distances (see 11.3); - adaption of the tables in Annex C and Annex D to the revised requirements and verification methods; - revision of the EMC requirements in Annex J; - shifting of tables from Annex H to new Annex N; - new Annex O with guidance on temperature rise verification; - new Annex P with a verification method for short-circuit withstand strength (integration of the content of IEC/TR 61117); - update of normative references; - general editorial review.