IEC 61442:1997

IEC 61442:1997

April 1997
International standard Cancelled

Electric cables - Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

Specifies the test methods to be used for type testing accessories for power cables with rated voltage from 3,6/6 (7,2) kV up to 18/30 (36) kV. Test methods are specified for accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055.

Main informations

Collections

International IEC standards

Publication date

April 1997

Number of pages

55 p.

Reference

IEC 61442:1997

ICS Codes

29.060.20   Cables
19.080   Electrical and electronic testing

Print number

1
Sumary
Electric cables - Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

Specifies the test methods to be used for type testing accessories for power cables with rated voltage from 3,6/6 (7,2) kV up to 18/30 (36) kV. Test methods are specified for accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055.
Standard replaced by (1)
IEC 61442:2005
March 2005
International standard Cancelled
Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

Specifies the test methods to be used for type testing accessories for power cables with rated voltage from 3,6/6 (7,2) kV up to 18/30 (36) kV. Test methods are specified for accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively. Significant technical changes with respect to the previous edition are as follows: a) a test in water has been added for stop ends; b) the heating cycles voltage test has been revised to clarify testing in air and water; c) the testing conditions for the short-circuit tests have been redefined; d) additional information has been provided for testing separable connectors with a metallic housing; e) tests not required by IEC, i.e. an immersion test for outdoor terminations and an impact test, have been included in order to have a common test method document with CENELEC under the IEC/CLC Dresden agreement.