IEC 61508-6:2000
IEC 61508-6:2000

IEC 61508-6:2000

April 2000
International standard Cancelled

Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see <a href="http://www.iec.ch/61508">www.iec.ch/61508</a>)

Contains information and guidelines on IEC 61508-2 and IEC 61508-3.

Main informations

Collections

International IEC standards

Publication date

April 2000

Number of pages

145 p.

Reference

IEC 61508-6:2000

ICS Codes

25.040.40   Industrial process measurement and control

Print number

1
Sumary
Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see www.iec.ch/61508)

Contains information and guidelines on IEC 61508-2 and IEC 61508-3.
Standard replaced by (1)
IEC 61508-6:2010
IEC 61508-6:2010
May 2010
International standard Current
Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508)

Looking for deeper insights? Check out IEC 61508:2010 CMV, which includes commented versions of Parts 1 to 7 of IEC 61508. These commented versions highlight the changes made from previous editions and provide explanations from a world-leading expert on the reasons behind the most significant changes. IEC 61508-6:2010 contains information and guidelines on IEC 61508-2 and IEC 61508 3. Annex A gives a brief overview of the requirements of IEC 61508-2 and IEC 61508-3 and sets out the functional steps in their application. Annex B gives an example technique for calculating the probabilities of hardware failure and should be read in conjunction with 7.4.3 and Annex C of IEC 61508-2 and Annex D. Annex C gives a worked example of calculating diagnostic coverage and should be read in conjunction with Annex C of IEC 61508-2. Annex D gives a methodology for quantifying the effect of hardware-related common cause failures on the probability of failure. Annex E gives worked examples of the application of the software safety integrity tables specified in Annex A of IEC 61508-3 for safety integrity levels 2 and 3. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. It has been subject to a thorough review and incorporates many comments received at the various revision stages. This publication is of high relevance for Smart Grid.

Need to identify, monitor and decipher standards?