IEC 61526:2010

IEC 61526:2010

July 2010
International standard Cancelled

Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters

IEC 61526:2010 specifies general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. The only requirements specified for associated readout systems are those which affect its accuracy of readout of the personal dose equivalent and alarm settings and those which concern the influence of the reader on the dosemeter. This new edition includes the following significant technical changes with regard to the previous one:- improved determination of constancy of the dose response and statistical fluctuations;- abolition of classes of personal dose equivalent meters in relation to retention of stored information;- inclusion of usage categories of personal dosemeters.

Main informations

Collections

International IEC standards

Publication date

July 2010

Number of pages

119 p.

Reference

IEC 61526:2010
Sumary
Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters

IEC 61526:2010 specifies general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. The only requirements specified for associated readout systems are those which affect its accuracy of readout of the personal dose equivalent and alarm settings and those which concern the influence of the reader on the dosemeter. This new edition includes the following significant technical changes with regard to the previous one:
- improved determination of constancy of the dose response and statistical fluctuations;
- abolition of classes of personal dose equivalent meters in relation to retention of stored information;
- inclusion of usage categories of personal dosemeters.
Replaced standards (1)
IEC 61526:2005
February 2005
International standard Cancelled
Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters and monitors

Specifies requirements for the dosemeter and, if supplied, for its associated readout system. Specifies general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. Also specifies classes of personal dose equivalent meters in relation to retention of stored information.

Standard replaced by (1)
IEC 61526:2024
March 2024
International standard Current
Radiation protection instrumentation - Measurement of personal dose equivalents for X, gamma, neutron and beta radiations - Active personal dosemeters

IEC 61526:2024 applies to personal dosemeters with the following characteristics: a) They are worn on the trunk, close to the eye, or on the extremities. b) They measure the personal dose equivalents Hp(10), Hp(3), and Hp(0,07), from external X and gamma, neutron (not for Hp(3)), and beta radiations, and may measure the respective personal dose equivalent rates for the same radiations (for alarming purposes). c) They have a digital indication. This indication may or may not be attached. d) They have alarm functions for the personal dose equivalents or personal dose equivalent rates except for hybrid dosemeters. For hybrid dosemeters an alarm function for the personal dose equivalents shall be implemented in the associated readout system. This document specifies requirements for the dosemeter and, if supplied, for its associated readout system. This document specifies, for the dosemeters described above, general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and envi­ronmental characteristics. This edition includes the following significant technical changes with respect to the previous edition: a) Modification of the title; b) Inclusion of the measurement quantity for the dose in the lens of the eye, Hp(3); c) Inclusion of measurement quantity for dose in the skin and extremities, Hp(0,07); d) Inclusion of dosemeters between active and passive: "hybrid dosemeters"; e) Inclusion of software requirements; f) Harmonization of requirements for linearity to IEC 62387; g) Revised neutron energy response requirements.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ