IEC 61534-1:2011

IEC 61534-1:2011

May 2011
International standard Current

Powertrack systems - Part 1: General requirements

IEC 61534-1:2011 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises. This second edition cancels and replaces the first edition published in 2003 and constitutes a technical revision. The main changes from the previous edition are as follows:- updated normative references (Clause 2);- changes to the number of samples to be tested (Subclause 5.3);- inclusion of a short circuit test (New Clause 18);- changes to external influences (Clause 21). The contents of the corrigendum apply to the French version only.

Main informations

Collections

International IEC standards

Publication date

May 2011

Number of pages

137 p.

Reference

IEC 61534-1:2011
Sumary
Powertrack systems - Part 1: General requirements

IEC 61534-1:2011 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises. This second edition cancels and replaces the first edition published in 2003 and constitutes a technical revision. The main changes from the previous edition are as follows:
- updated normative references (Clause 2);
- changes to the number of samples to be tested (Subclause 5.3);
- inclusion of a short circuit test (New Clause 18);
- changes to external influences (Clause 21). The contents of the corrigendum apply to the French version only.
Replaced standards (1)
IEC 61534-1:2003
June 2003
International standard Cancelled
Powertrack systems - Part 1: General requirements

This part of IEC 61534 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz, with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises.