IEC 61557-13:2023

IEC 61557-13:2023

August 2023
International standard Current

Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems

IEC 61557-13:2023 defines special performance requirements for hand-held and hand manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems up to 1 000 V AC and 1 500 V DC taking into account the influence of high external low-frequency magnetic fields and other influencing quantities. See Annex A for examples of measurement applications.This document does not apply to current clamps or sensors that are used in combination with devices for insulation fault location in accordance with IEC 61557-9, unless it is specified by the manufacturer.IEC 61557-13:2023 cancels and replaces the first edition published in 2011. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:a) the term "fixing device" has been removed;b) the measuring range was changed to a display range, the indication of DC or peak values has been added in 4.1;c) the frequency for the test of sensitivity for low-frequency magnetic fields has been defined in 4.2;d) the specified measuring range is now defined as the range of indicated values based on the operating uncertainty in 4.3;e) alignment of the structure with that of the whole IEC 61557 series;f) the variation E12 (maximum load current), may be specified according to the manufacturer?s specification.

Main informations

Collections

International IEC standards

Publication date

August 2023

Number of pages

41 p.

Reference

IEC 61557-13:2023
Sumary
Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems

IEC 61557-13:2023 defines special performance requirements for hand-held and hand manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems up to 1 000 V AC and 1 500 V DC taking into account the influence of high external low-frequency magnetic fields and other influencing quantities. See Annex A for examples of measurement applications.
This document does not apply to current clamps or sensors that are used in combination with devices for insulation fault location in accordance with IEC 61557-9, unless it is specified by the manufacturer.
IEC 61557-13:2023 cancels and replaces the first edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the term "fixing device" has been removed;
b) the measuring range was changed to a display range, the indication of DC or peak values has been added in 4.1;
c) the frequency for the test of sensitivity for low-frequency magnetic fields has been defined in 4.2;
d) the specified measuring range is now defined as the range of indicated values based on the operating uncertainty in 4.3;
e) alignment of the structure with that of the whole IEC 61557 series;
f) the variation E12 (maximum load current), may be specified according to the manufacturer?s specification.
Replaced standards (1)
IEC 61557-13:2011
July 2011
International standard Cancelled
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 13: Hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems

IEC 61557-13:2011 defines special performance requirements for hand-held and hand-manipulated current clamps and sensors for measurement of leakage currents in electrical distribution systems up to 1 000 V a.c. and 1 500 V d.c., taking into account the influence of high external low-frequency magnetic fields and other influencing quantities. This standard does not apply to current clamps or sensors which are used in combination with devices for insulation fault location according to IEC 61557-9, unless it is specified by the manufacturer.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ