IEC 61557-3:2007

IEC 61557-3:2007

January 2007
International standard Cancelled

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance

This part of IEC 61557 specifies the requirements applicable to equipment for measuring the loop impedance between a phase conductor and the protective conductor or between a phase conductor and neutral or between two phase conductors by using the voltage drop when the circuit under test is loaded. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. The following changes were made with respect to the previous edition: a) definitions complemented; b) revision of some requirements; c) addition of information on operating instructions; d) addition of new influence quantities E9 and E10.

Main informations

Collections

International IEC standards

Publication date

January 2007

Number of pages

19 p.

Reference

IEC 61557-3:2007
Sumary
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance

This part of IEC 61557 specifies the requirements applicable to equipment for measuring the loop impedance between a phase conductor and the protective conductor or between a phase conductor and neutral or between two phase conductors by using the voltage drop when the circuit under test is loaded. This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision. The following changes were made with respect to the previous edition: a) definitions complemented; b) revision of some requirements; c) addition of information on operating instructions; d) addition of new influence quantities E9 and E10.
Replaced standards (1)
IEC 61557-3:1997
February 1997
International standard Cancelled
Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance

Specifies requirements for equipment for measuring the loop impedance between a phase conductor and the protective conductor or between a phase conductor and neutral or between two phase conductors by using the voltage drop when the circuit under test is loaded.

Standard replaced by (1)
IEC 61557-3:2019
July 2019
International standard Current
Electrical safety in low voltage distribution systems up to 1 000 V AC and 1 500 V DC - Equipment for testing, measuring or monitoring of protective measures - Part 3: Loop impedance

IEC 61557-3:2019 specifies the requirements applicable to equipment for measuring the loop impedance between a line conductor and protective conductor; between a line conductor and neutral; or between two line conductors by using the voltage drop when the circuit under test is loaded. IEC 61557-3:2019 cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of equirements as regards the measurement category; b) addition of new requirements for operating instructions; c) alignment of the structure with that of the whole IEC 61557 series.