IEC 61557-9:2014
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems
IEC 61557-9:2014 specifies the requirements for the insulation fault location system (IFLS) which localizes insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1 000 V a.c., as well as in unearthed IT d.c. systems with voltages up to 1 500 V d.c., independent of the measuring principle. IT systems are described in IEC 60364-4-41 amongst other literature. Additional data for a selection of devices in other standards should be noted. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:- the scope, normative references, terms and definitions have been complemented;- abbreviations are listed and explained;- requirements, marking and operating instructions have been revised;- mandatory and optional functions have been defined and their terminology has been adapted to IEC 61557-15;- mechanical requirements have been added;- Clause 6 "Tests" has been revised; and- new Tables have been added.This publication is to be read in conjunction with IEC 61557-1:2007. The contents of the corrigenda of May 2016 and of January 2017 have been included in this copy.
IEC 61557-9:2014 specifies the requirements for the insulation fault location system (IFLS) which localizes insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1 000 V a.c., as well as in unearthed IT d.c. systems with voltages up to 1 500 V d.c., independent of the measuring principle. IT systems are described in IEC 60364-4-41 amongst other literature. Additional data for a selection of devices in other standards should be noted. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- the scope, normative references, terms and definitions have been complemented;
- abbreviations are listed and explained;
- requirements, marking and operating instructions have been revised;
- mandatory and optional functions have been defined and their terminology has been adapted to IEC 61557-15;
- mechanical requirements have been added;
- Clause 6 "Tests" has been revised; and
- new Tables have been added.
This publication is to be read in conjunction with IEC 61557-1:2007. The contents of the corrigenda of May 2016 and of January 2017 have been included in this copy.
IEC 61557-9:2009 specifies the requirements for insulation fault location systems which localize insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1 000 V a.c., as well as in unearthed IT d.c. systems with voltages up to 1 500 V d.c., independent of the measuring principle. This second edition cancels and replaces the first edition published in 1999. It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - scope, normative references and terms and definitions complemented; - revision of requirements, marking and operating instructions and Clause 6; - revision of Table 1; - addition of Annexes A, B and C.
IEC 61557-9:2023 specifies the requirements for the insulation fault location system (IFLS) that localizes insulation faults in any part of the system in unearthed IT AC systems and unearthed IT AC systems with galvanically connected DC circuits having nominal voltages up to 1 000 V AC, as well as in unearthed IT DC systems with voltages up to 1 500 V DC, independent of the measuring principle. IEC 61557-9:2023 cancels and replaces the third edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) new terms and definitions on maximum admissible locating AC and DC currents and voltages; b) the requirements on locating current and locating voltage have been revised; c) performance requirements have been added; d) the test requirements for locating current and locating voltage have been revised; e) the structure of this document has been adapted to that of IEC 61557-1:2019; f) the limit values under Clause A.2 were adapted to fit the changed test methods in 6.2.3.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ