IEC 61788-13:2012
Superconductivity - Part 13: AC loss measurements - Magnetometer methods for hysteresis loss in superconducting multifilamentary composites
IEC 61788-13:2012 describes considerations for the measurement of hysteretic loss in Cu/Nb-Ti multifilamentary composites using DC- or low-ramp-rate magnetometry. This international standard specifies a method of the measurement of hysteretic loss in multifilamentary Cu/Nb-Ti composite conductors. Measurements are assumed to be on round wires with temperatures at or near 4,2 K. DC or low-ramp-rate magnetometry will be performed using either a superconducting quantum interference device or a vibrating-sample magnetometer. Extension to the measurement of superconductors in general is given in Annex. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. Modifications made to the second edition extend to the measurement of superconductors in general, in various sample sizes and shapes, and at temperatures other than 4,2 K, and use the word "uncertainty" for all quantitative statistical expressions to eliminate the quantitative use of "precision" and "accuracy".
IEC 61788-13:2012 describes considerations for the measurement of hysteretic loss in Cu/Nb-Ti multifilamentary composites using DC- or low-ramp-rate magnetometry. This international standard specifies a method of the measurement of hysteretic loss in multifilamentary Cu/Nb-Ti composite conductors. Measurements are assumed to be on round wires with temperatures at or near 4,2 K. DC or low-ramp-rate magnetometry will be performed using either a superconducting quantum interference device or a vibrating-sample magnetometer. Extension to the measurement of superconductors in general is given in Annex. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. Modifications made to the second edition extend to the measurement of superconductors in general, in various sample sizes and shapes, and at temperatures other than 4,2 K, and use the word "uncertainty" for all quantitative statistical expressions to eliminate the quantitative use of "precision" and "accuracy".
Describes considerations for the measurement of hysteretic loss in Cu/Nb-Ti multifilamentary composites using DC- or low-ramp-rate magnetometry. Focuses on the measurement of hysteretic loss in multifilamentary Cu/Nb-Ti composite conductors. Measurements are assumed to be on round wires with temperatures at or near 4,2 K. DC or low-ramp-rate magnetometry will be performed using either a superconducting quantum interference device (SQUID magnetometer) or a vibrating-sample magnetometer (VSM). In case differences between the calibrated magnetometer results are noted, the VSM results, extrapolated to zero ramp rate, will be taken as definitive.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ