IEC 61869-5:2011

IEC 61869-5:2011

July 2011
International standard Current

Instrument transformers - Part 5: Additional requirements for capacitor voltage transformers

IEC 61869-5:2011 applies to new single-phase capacitor voltage transformers connected between line and ground for system voltages Um ≥ 72,5 kV at power frequencies from 15 Hz to 100 Hz. They are intended to supply a low voltage for measurement, control and protective functions. This standard replaces IEC 60044-5 regarding capacitor voltage transformers as well as IEC-PAS 60044-5 for capacitor voltage transformers.This publication is to be read in conjunction with IEC 61869-1:2007. The contents of the corrigendum of August 2015 have been included in this copy.

Main informations

Collections

International IEC standards

Publication date

July 2011

Number of pages

106 p.

Reference

IEC 61869-5:2011

ICS Codes

17.220.20   Measurement of electrical and magnetic quantities
Sumary
Instrument transformers - Part 5: Additional requirements for capacitor voltage transformers

IEC 61869-5:2011 applies to new single-phase capacitor voltage transformers connected between line and ground for system voltages Um ≥ 72,5 kV at power frequencies from 15 Hz to 100 Hz. They are intended to supply a low voltage for measurement, control and protective functions. This standard replaces IEC 60044-5 regarding capacitor voltage transformers as well as IEC-PAS 60044-5 for capacitor voltage transformers.

This publication is to be read in conjunction with IEC 61869-1:2007. The contents of the corrigendum of August 2015 have been included in this copy.
Replaced standards (1)
IEC 60044-5:2004
April 2004
International standard Cancelled
Instrument transformers - Part 5: Capacitor voltage transformers

This part of IEC 60044 applies to new single-phase capacitor voltage transformers connected between line and ground for system voltages Um 72,5 kV at power frequencies from 15 Hz to 100 Hz. They are intended to supply a low voltage for measurement, control and protective functions. The capacitor voltage transformer can be equipped with or without carrier-frequency accessories for power line carrier-frequency (PLC) application at carrier frequencies from 30 kHz to 500 kHz.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ