IEC 62037-3:2021

IEC 62037-3:2021

November 2021
International standard Cancelled

Passive RF and microwave devices, intermodulation level measurement - Part 3: Measurement of passive intermodulation in coaxial connectors

IEC 62037-3:2021 defines the impact test on coaxial connectors to evaluate their robustness against weak connections and particles inside the connector, as independently as possible from the effects of cable PIM (passive intermodulation). For other connectors (e.g. panel mounted connectors), the cable can be replaced by an adequate transmission-line (e.g. airline, stripline). In order to evaluate the effects of mechanical stresses on the connectors, a series of impacts is applied to the connectors while measuring the PIM. This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition:a. impact method changed to utilize a steel ball rather than a brass rod;b. impact energy required to test each connector type added;c. method added to calculate impact energy for connector types not listed in the document.

Main informations

Collections

International IEC standards

Publication date

November 2021

Number of pages

17 p.

Reference

IEC 62037-3:2021
Sumary
Passive RF and microwave devices, intermodulation level measurement - Part 3: Measurement of passive intermodulation in coaxial connectors

IEC 62037-3:2021 defines the impact test on coaxial connectors to evaluate their robustness against weak connections and particles inside the connector, as independently as possible from the effects of cable PIM (passive intermodulation). For other connectors (e.g. panel mounted connectors), the cable can be replaced by an adequate transmission-line (e.g. airline, stripline). In order to evaluate the effects of mechanical stresses on the connectors, a series of impacts is applied to the connectors while measuring the PIM. This second edition cancels and replaces the first edition published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
a. impact method changed to utilize a steel ball rather than a brass rod;
b. impact energy required to test each connector type added;
c. method added to calculate impact energy for connector types not listed in the document.
Replaced standards (1)
IEC 62037-3:2012
July 2012
International standard Cancelled
Passive RF and microwave devices, intermodulation level measurement - Part 3: Measurement of passive intermodulation in coaxial connectors

IEC 62037-3:2012 is part of the IEC 62037 series, and defines the impact test on coaxial connectors to evaluate their robustness against weak connections and particles inside the connector as independently as possible from the effects of cable PIM (passive intermodulation).

Standard replaced by (1)
IEC 62037-3:2025
March 2025
International standard Current
Passive RF and microwave devices, intermodulation level measurement - Part 3: Measurement of passive intermodulation in coaxial connectors

IEC 62037-3:2025 defines the impact test on coaxial connectors to evaluate their robustness against weak connections and particles inside the connector, as independently as possible from the effects of cable passive intermodulation (PIM). For other connectors (e.g. panel mounted connectors), the cable can be replaced by an adequate transmission line (e.g. airline, stripline). In order to evaluate the effects of mechanical stresses on the connectors, a series of impacts is applied to the connectors while measuring the PIM. This third edition cancels and replaces the second edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) impact test requirements for multi-channel connectors added; b) method for calculating impact energy added for connector shapes other than round; c) revised test considerations for achieving maximum PIM in reverse (reflected) PIM measurements; d) added clarification that PIM tests reports shall include the maximum PIM value measured.