IEC 62040-1:2008

IEC 62040-1:2008

June 2008
International standard Cancelled

Uninterruptible power systems (UPS) - Part 1: General and safety requirements for UPS

IEC 62040-1:2008 applies to uninterruptible power systems (UPS) with an electrical energy storage device in the d.c. link. It is used with IEC 60950-1, which is referred to in this standard as "RD" (reference document). It is applicable to UPS which are movable, stationary, fixed or for building-in, for use in low-voltage distribution systems and intended to be installed in any operator accessible area or in restricted access locations as applicable. It specifies requirements to ensure safety for the operator and layman who may come into contact with the equipment and, where specifically stated, for the service person. It cancels and replaces the first edition of IEC 62040-1-1, published in 2004 and IEC 62040-1-2, published in 2004 and constitutes a technical revision. This standard merges all requirements of previous IEC 62040-1-1 and IEC 62040-1-2, with the addition of the following:- update of normative references including IEC 60950-1 as Reference Document (RD);- harmonization and alignment with current world recognized best practices;- enhancement of backfeed protection, definition of ground-fault, revision of temperature rise tables and of hydrogen concentration in battery compartments.The contents of the corrigendum of September 2008 have been included in this copy.

Main informations

Collections

International IEC standards

Publication date

June 2008

Number of pages

123 p.

Reference

IEC 62040-1:2008

Print number

1
Sumary
Uninterruptible power systems (UPS) - Part 1: General and safety requirements for UPS

IEC 62040-1:2008 applies to uninterruptible power systems (UPS) with an electrical energy storage device in the d.c. link. It is used with IEC 60950-1, which is referred to in this standard as "RD" (reference document). It is applicable to UPS which are movable, stationary, fixed or for building-in, for use in low-voltage distribution systems and intended to be installed in any operator accessible area or in restricted access locations as applicable. It specifies requirements to ensure safety for the operator and layman who may come into contact with the equipment and, where specifically stated, for the service person. It cancels and replaces the first edition of IEC 62040-1-1, published in 2004 and IEC 62040-1-2, published in 2004 and constitutes a technical revision. This standard merges all requirements of previous IEC 62040-1-1 and IEC 62040-1-2, with the addition of the following:
- update of normative references including IEC 60950-1 as Reference Document (RD);
- harmonization and alignment with current world recognized best practices;
- enhancement of backfeed protection, definition of ground-fault, revision of temperature rise tables and of hydrogen concentration in battery compartments. The contents of the corrigendum of September 2008 have been included in this copy.
Replaced standards (4)
International standard Cancelled
Corrigendum 1 - Uninterruptible power systems (UPS) - Part 1-1: General and safety requirements for UPS used in operator access areas

International standard Cancelled
Corrigendum 2 - Uninterruptible power systems (UPS) - Part 1-1: General and safety requirements for UPS used in operator access areas

International standard Cancelled
Corrigendum 1 - Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS used in restricted access locations

International standard Cancelled
Corrigendum 2 - Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS used in restricted access locations

See more
Standard replaced by (1)
IEC 62040-1:2017
July 2017
International standard Current
Uninterruptible power systems (UPS) - Part 1: Safety requirements

IEC 62040-1:2017 applies to movable, stationary, fixed or built-in UPS for use in low-voltage distribution systems and that are intended to be installed in an area accessible by an ordinary person or in a restricted access area as applicable, that deliver fixed frequency AC output voltage with port voltages not exceeding 1 000 V AC or 1 500 V DC and that include an energy storage device. It applies to pluggable and to permanently connected UPS, whether consisting of a system of interconnected units or of independent units, subject to installing, operating and maintaining the UPS in the manner prescribed by the manufacturer. This document specifies requirements to ensure safety for the ordinary person who comes into contact with the UPS and, where specifically stated, for the skilled person. The objective is to reduce risks of fire, electric shock, thermal, energy and mechanical hazards during use and operation and, where specifically stated, during service and maintenance. This product standard is harmonized with the applicable parts of group safety publication IEC 62477-1:2012 for power electronic converter systems and contains additional requirements relevant to UPS. This edition includes the following significant technical change with respect to the previous edition: the reference document has been changed from IEC 60950-1:2005 (safety for IT equipment) to IEC 62477-1 (group safety standard for power electronic converters). The contents of the corrigendum of October 2019 have been included in this copy.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ