IEC 62127-2:2025

IEC 62127-2:2025

January 2025
International standard Current

Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields

IEC 62127-2:2025 specifies:- absolute hydrophone calibration methods;- relative (comparative) hydrophone calibration methods.Recommendations and references to accepted literature are made for the various relative and absolute calibration methods in the frequency range covered by this document.This document is applicable to- hydrophones used for measurements made in water and in the ultrasonic frequency range 50 kHz to 100 MHz;- hydrophones employing piezoelectric sensor elements, designed to measure the pulsed wave and continuous wave ultrasonic fields generated by ultrasonic equipment;- hydrophones with or without a hydrophone pre-amplifier.IEC 62127-2:2025 cancels and replaces the first edition published in 2007, Amendment 1:2013 and Amendment 2:2017. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:a) the upper frequency limit of 40 MHz has been removed;b) hydrophone sensitivity definitions have been changed to recognize sensitivities as complex-valued quantities;c) directional response measurement and effective size determination procedures have been updated in 12.5.1 to align with recent changes in IEC 62127-3;d) Annex F has been amended to comprise a calibration technique for high-frequency complex-valued calibration;e) the reciprocity method description in Annex K was extended to also comprise focusing transducers.

Main informations

Collections

International IEC standards

Publication date

January 2025

Number of pages

234 p.

Reference

IEC 62127-2:2025
Sumary
Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields

IEC 62127-2:2025 specifies:
- absolute hydrophone calibration methods;
- relative (comparative) hydrophone calibration methods.
Recommendations and references to accepted literature are made for the various relative and absolute calibration methods in the frequency range covered by this document.
This document is applicable to
- hydrophones used for measurements made in water and in the ultrasonic frequency range 50 kHz to 100 MHz;
- hydrophones employing piezoelectric sensor elements, designed to measure the pulsed wave and continuous wave ultrasonic fields generated by ultrasonic equipment;
- hydrophones with or without a hydrophone pre-amplifier.
IEC 62127-2:2025 cancels and replaces the first edition published in 2007, Amendment 1:2013 and Amendment 2:2017. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) the upper frequency limit of 40 MHz has been removed;
b) hydrophone sensitivity definitions have been changed to recognize sensitivities as complex-valued quantities;
c) directional response measurement and effective size determination procedures have been updated in 12.5.1 to align with recent changes in IEC 62127-3;
d) Annex F has been amended to comprise a calibration technique for high-frequency complex-valued calibration;
e) the reciprocity method description in Annex K was extended to also comprise focusing transducers.
Replaced standards (4)
International standard Cancelled
Amendment 1 - Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz

International standard Cancelled
Amendment 2 - Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz

IEC 62127-2:2007
August 2007
International standard Cancelled
Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz

IEC 62127-2:2007 specifies absolute hydrophone calibration methods and relative (comparative) hydrophone calibration methods. This standard is applicable to: - hydrophones used for measurements made in water and in the ultrasonic frequency range up to 40 MHz; - hydrophones employing circular piezoelectric sensor elements, designed to measure the pulsed wave and continuous wave ultrasonic fields generated by ultrasonic equipment; - and hydrophones with or without a hydrophone pre-amplifier. IEC 62127-1, IEC 62127-2 and IEC 62127-3 are being published simultaneously. Together these cancel and replace IEC 60866:1987, IEC 61101:1991, IEC 61102:1991, IEC 61220:1993 and IEC 62092:2001. The contents of the corrigendum of August 2008 have been included in this copy. The French version of this standard has not been voted upon.

International standard Cancelled
Corrigendum 1 - Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz

See more