IEC 62153-4-5:2021

IEC 62153-4-5:2021

August 2021
International standard Current

Metallic communication cable test methods - Part 4-5: Electromagnetic compatibility (EMC) - Screening or coupling attenuation - Absorbing clamp method

IEC 62153-4-5:2021 is suitable to determine the screening- or the coupling-attenuation of metallic communication cables in the frequency range of 30 MHz to 1 000 MHz (2 400 MHz), depending on the performance of the clamp. It is an alternative method to the triaxial method of IEC 62153-4-4 or IEC 62153-4-9. Due to the undefined outer circuit of this absorbing clamp method, the test results obtained at different places and laboratories could vary by at least ± 6 dB.This second edition cancels and replaces the first edition published in 2006. This edition includes the following significant technical changes with respect to the previous edition:a. reorganisation of clauses and annexes;b. extension of frequency range to 2,4 GHz;c. application of a virtual balun respectively balunless test procedure with multiport VNA.

Main informations

Collections

International IEC standards

Publication date

August 2021

Number of pages

81 p.

Reference

IEC 62153-4-5:2021
Sumary
Metallic communication cable test methods - Part 4-5: Electromagnetic compatibility (EMC) - Screening or coupling attenuation - Absorbing clamp method

IEC 62153-4-5:2021 is suitable to determine the screening- or the coupling-attenuation of metallic communication cables in the frequency range of 30 MHz to 1 000 MHz (2 400 MHz), depending on the performance of the clamp. It is an alternative method to the triaxial method of IEC 62153-4-4 or IEC 62153-4-9. Due to the undefined outer circuit of this absorbing clamp method, the test results obtained at different places and laboratories could vary by at least ± 6 dB.
This second edition cancels and replaces the first edition published in 2006. This edition includes the following significant technical changes with respect to the previous edition:
a. reorganisation of clauses and annexes;
b. extension of frequency range to 2,4 GHz;
c. application of a virtual balun respectively balunless test procedure with multiport VNA.
Replaced standards (1)
IEC 62153-4-5:2006
March 2006
International standard Cancelled
Metallic communication cables test methods - Part 4-5: Electromagnetic compatibility (EMC) - Coupling or screening attenuation - Absorbing clamp method

determines the coupling or screening attenuation of metallic communication cables in the frequency range of 30 MHz to 1 000 MHz. It is an alternative method to the injection clamp method of IEC 62153-4-3 or the triaxial method of IEC/ PAS 62338. Due to the undefined outer circuit of this absorbing clamp method, the test results obtained at different places and laboratories could vary by at least ±6dB.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ