IEC 62153-4-7:2015

IEC 62153-4-7:2015

December 2015
International standard Cancelled

Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method

IEC 62153-4-7:2015 describes a triaxial method, suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and multicore cable assemblies. For the measurement of transfer impedance and screening- or coupling attenuation, only one test set-up is needed. This edition includes the following significant technical changes with respect to the previous edition:The document is revised and updated. The changes of the revised IEC 62153-4-3:2013, and IEC 62153-4-4:2015, are included. Measurements can be achieved now with mismatch at the generator site, impedance matching devices are not necessary. The contents of the corrigendum of April 2016 have been included in this copy.

Main informations

Collections

International IEC standards

Publication date

December 2015

Number of pages

83 p.

Reference

IEC 62153-4-7:2015

Print number

2
Sumary
Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance ZT and screening attenuation aS or coupling attenuation aC of connectors and assemblies up to and above 3 GHz - Triaxial tube in tube method

IEC 62153-4-7:2015 describes a triaxial method, suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and multicore cable assemblies. For the measurement of transfer impedance and screening- or coupling attenuation, only one test set-up is needed. This edition includes the following significant technical changes with respect to the previous edition:
The document is revised and updated. The changes of the revised IEC 62153-4-3:2013, and IEC 62153-4-4:2015, are included. Measurements can be achieved now with mismatch at the generator site, impedance matching devices are not necessary. The contents of the corrigendum of April 2016 have been included in this copy.
Replaced standards (1)
IEC 62153-4-7:2006
April 2006
International standard Cancelled
Metallic communication cable test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring the transfer impedance and the screening - or the coupling attenuation - Tube in tube method

is suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and cable assemblies.

Standard replaced by (1)
IEC 62153-4-7:2021
July 2021
International standard Current
Metallic cables and other passive components test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance Z<sub>T</sub> and screening attenuation a<sub>S</sub> or coupling attenuation a<sub>C</sub> of connectors and assemblies - Triaxial tube in tube method

IEC 62153-4-7:2021 deals with the triaxial tube in tube method. This triaxial method is suitable to determine the surface transfer impedance and/or screening attenuation and coupling attenuation of mated screened connectors (including the connection between cable and connector) and cable assemblies. This method could also be extended to determine the transfer impedance, coupling or screening attenuation of balanced or multipin connectors and multicore cable assemblies. This third edition cancels and replaces the second edition published in 2015 and its Amendment 1:2018.This edition includes the following significant technical changes with respect to the previous edition: - Annex E contains informative information about the direct measurement of screening effectiveness of connectors; - Annex F gives normative information about mixed mode parameters; - Annex G contains normative information about accessories for measuring coupling attenuation; - Annex H discusses the low frequency screening attenuation.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ