IEC 62271-105:2002

IEC 62271-105:2002

August 2002
International standard Cancelled

High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations

Applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses designed so as to be capable of- breaking, at the rated recovery voltage, any current up to and including the rated short-circuit breaking current,- making, at the rated voltage, circuits to which the rated short-circuit breaking current applies.It does not apply to fuse-circuit-breakers, fuse-contactors, combinations for motor-circuits or to combinations incorporatingsingle capacitor bank switches.

Main informations

Collections

International IEC standards

Publication date

August 2002

Number of pages

95 p.

Reference

IEC 62271-105:2002

Print number

1
Sumary
High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations

Applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses designed so as to be capable of - breaking, at the rated recovery voltage, any current up to and including the rated short-circuit breaking current, - making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. It does not apply to fuse-circuit-breakers, fuse-contactors, combinations for motor-circuits or to combinations incorporatingsingle capacitor bank switches.
Replaced standards (1)
IEC 60420:1990
October 1990
International standard Cancelled
High-voltage alternating current switch-fuse combinations

This standard applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses and thus able to interrupt: -any load current up to the rated breaking current of the switch; -any over-current up to the rated short-circuit breaking current of the combination by which automatic interruption is initiated. This standard applies to combinations designed with rated voltages above 1 kV and below 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz.

Standard replaced by (1)
IEC 62271-105:2012
September 2012
International standard Cancelled
High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV

IEC 62271-105:2012 applies to three-pole units for public and industrial distribution systems which are functional assemblies of switches including switch-disconnectors and current-limiting fuses designed so as to be capable of - breaking, at the rated recovery voltage, any current up to and including the rated short-circuit breaking current; - making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. It does not apply to fuse-circuit-breakers, fuse-contactors, combinations for motor-circuits or to combinations incorporating single capacitor bank switches. This second edition cancels and replaces the first edition of IEC 62271-105, published in 2002, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - implementation of figures at the place where they are cited first; - renumbering of tables; - addition of some of the proposals from IEC paper 17A/852/INF; - addition of missing subclauses of IEC 62271-1; - implementation of 6.105 "Extension of validity of type tests" and consequently removing of the relevant parts in the different existing clauses; - change of 7th paragraph of 6.101.4 as there is now a definition of NSDD given in 3.7.4 of IEC 62271-1:2007. Harmonization with IEC 62271-107; - some referenced clauses in other standards like IEC 60282-1 were changed and therefore changed the editions under 1.2 to the ones referred to; - addition of a new Annex C defining tolerances. This publication is to be read in conjunction with IEC 62271-1:2007.