IEC 62305-3:2006
Protection against lightning - Part 3: Physical damage to structures and life hazard
Provides the requirements for protection of a structure against physical damage by means of a lightning protection system (LPS), and for protection against injury to living beings due to touch and step voltages in the vicinity of an LPS (see IEC 62305-1). This standard is applicable to: a) design, installation, inspection and maintenance of an LPS for structures without limitation of their height; b) establishment of measures for protection against injury to living beings due to touch and step voltages.
Provides the requirements for protection of a structure against physical damage by means of a lightning protection system (LPS), and for protection against injury to living beings due to touch and step voltages in the vicinity of an LPS (see IEC 62305-1). This standard is applicable to: a) design, installation, inspection and maintenance of an LPS for structures without limitation of their height; b) establishment of measures for protection against injury to living beings due to touch and step voltages.
This standard is applicable to the design and installation of Lightning Protection Systems (LPS) for common structures up to 60 m high.
Applicable to the design and installation of Lightning Protection Systems (SPS) for common structures up to 60 m high, in accordance with IEC 61024-1. Provides guidelines on how to use IEC 61024-1 and assists the user with the physical design and construction, maintenance and inspection of an LPS
IEC 62305-3:2010 provides the requirements for protection of a structure against physical damage by means of a lightning protection system (LPS), and for protection against injury to living beings due to touch and step voltages in the vicinity of an LPS (see IEC 62305-1). This second edition cancels and replaces the first edition, published in 2006, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: 1) Minimum thicknesses of metal sheets or metal pipes given in Table 3 for air-termination systems are assumed as not able to prevent hot-spot problems. 2) Steel with electro-deposited copper is introduced as material suitable for LPS. 3) Some cross-sectional areas of LPS conductors were slightly modified. 4) For bonding purposes, isolating spark gaps are used for metal installations and SPD for internal systems. 5) Two methods simplified and detailed are provided for evaluation of separation distance. 6) Protection measures against injuries of living beings due to electric shock are considered also inside the structure. 7) Improved information for LPS in the case of structures with a risk of explosion are given in Annex D (normative). This bilingual version (2012-06) corresponds to the monolingual English version, published in 2010-12.