Photovoltaic (PV) arrays - Design requirements

IEC 62548:2016 sets out design requirements for photovoltaic (PV) arrays including DC array wiring, electrical protection devices, switching and earthing provisions. The scope includes all parts of the PV array up to but not including energy storage devices, power conversion equipment or loads. An exception is that provisions relating to power conversion equipment are covered only where DC safety issues are involved. The interconnection of small DC conditioning units intended for connection to PV modules are also included. The object of this document is to address the design safety requirements arising from the particular characteristics of photovoltaic systems. Direct current systems, and PV arrays in particular, pose some hazards in addition to those derived from conventional AC power systems, including the ability to produce and sustain electrical arcs with currents that are not greater than normal operating currents.

Main informations

Collections

International IEC standards

Publication date

September 2016

Number of pages

144 p.

Reference

IEC 62548:2016
Sumary
Photovoltaic (PV) arrays - Design requirements

IEC 62548:2016 sets out design requirements for photovoltaic (PV) arrays including DC array wiring, electrical protection devices, switching and earthing provisions. The scope includes all parts of the PV array up to but not including energy storage devices, power conversion equipment or loads. An exception is that provisions relating to power conversion equipment are covered only where DC safety issues are involved. The interconnection of small DC conditioning units intended for connection to PV modules are also included. The object of this document is to address the design safety requirements arising from the particular characteristics of photovoltaic systems. Direct current systems, and PV arrays in particular, pose some hazards in addition to those derived from conventional AC power systems, including the ability to produce and sustain electrical arcs with currents that are not greater than normal operating currents.
Replaced standards (1)
IEC TS 62548:2013
July 2013
Technical specification Cancelled
Photovoltaic (PV) arrays - Design requirements

IEC/TS 62548:2013(E) sets out design requirements for photovoltaic (PV) arrays including d.c. array wiring, electrical protection devices, switching and earthing provisions. The scope includes all parts of the PV array up to but not including energy storage devices, power conversion equipment or loads. The object of this Technical Specification is to address the design safety requirements arising from the particular characteristics of photovoltaic systems. Attention is drawn to a project in the IEC 60364 series under joint development between IEC TCs 64 and 82, which will, when published, cancel and replace the present technical specification.

Standard replaced by (1)
IEC 62548-1:2023
December 2023
International standard Current
Photovoltaic (PV) arrays - Part 1: Design requirements

IEC 62548-1:2023 sets out design requirements for photovoltaic (PV) arrays including DC array wiring, electrical protection devices, switching and earthing provisions. The scope includes all parts of the PV array and final power conversion equipment (PCE), but not including energy storage devices, loads or AC or DC distribution network supplying loads. The object of this document is to address the design safety requirements arising from the particular characteristics of photovoltaic systems. This document also includes extra protection requirements of PV arrays when they are directly connected with batteries at the DC level. This first edition cancels and replaces IEC 62548 published in 2016. This edition includes the following significant technical changes with respect to the previous edition: a) Revised provisions for systems including DC to DC conditioning units. b) Revision of mounting structure requirements. c) Revised cable requirements. d) Revision of Clause 6 on safety issues which includes provisions for protection against electric shock including array insulation monitoring and earth fault detection. e) Revision of 7.2.7 and 7.3 with respect to isolation means. f) Provisions for use of bifacial modules and modules mounted in non-optimal orientations. g) New Annex F containing: KI factor calculations for bifacial and non-optimally oriented systems; anti-PID equipment and arc flash.