IEC 63522-13:2024
Electrical relays - Tests and measurements - Part 13: Corrosive atmospheres due to sulfur impact
IEC 63522-13:2024 is used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combinations of these) and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.This document defines a standard test method to simulate impacts of sulfuric atmospheres to relays. The test conditions simulate an artificial situation and allow a performance comparison for usability of the devices under test (DUT) with regard to known and existing switching solutions.The test is a static test without actual operation of the DUT to simulate a worst-case scenario for corrosion, since corrosion increases over time. The corrosion layer can potentially create contact sticking, increase resistance or other undesired effects in the relay. Those aspects can be affected by DUT actuations during the test, which can destroy the corrosion layers or hide relevant long-term effects.In addition to polluted atmospheres, the suitability of the DUT for use and/or storage in corrosive atmospheres can be assessed in a salt-laden atmosphere as described in IEC 63522-44.
IEC 63522-13:2024 is used for testing electromechanical elementary relays (electromechanical relays, reed relays, reed contacts, reed switches and technology combinations of these) and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method to simulate impacts of sulfuric atmospheres to relays. The test conditions simulate an artificial situation and allow a performance comparison for usability of the devices under test (DUT) with regard to known and existing switching solutions.
The test is a static test without actual operation of the DUT to simulate a worst-case scenario for corrosion, since corrosion increases over time. The corrosion layer can potentially create contact sticking, increase resistance or other undesired effects in the relay. Those aspects can be affected by DUT actuations during the test, which can destroy the corrosion layers or hide relevant long-term effects.
In addition to polluted atmospheres, the suitability of the DUT for use and/or storage in corrosive atmospheres can be assessed in a salt-laden atmosphere as described in IEC 63522-44.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ