IEC TS 60076-14:2009
IEC TS 60076-14:2009

IEC TS 60076-14:2009

May 2009
Technical specification Cancelled

Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials

IEC 60076-14:2009(E) provides specification, design, testing and loading information for use by both the manufacturer and user of liquid-immersed power transformers employing either high-temperature insulation or combinations of high-temperature and conventional insulation. Is applicable to:- power transformers designed in accordance with IEC 60076-1,- convertor transformers designed to IEC 61378 series,- arc furnace transformers,- and covers the use of various liquid and solid insulation combinations. This new edition includes the following significant technical changes with respect to the previous edition:- enhancement of insulation system descriptions;- clarification of temperature rise limits- and the addition of overload temperature limits.

Main informations

Collections

International IEC standards

Publication date

May 2009

Number of pages

44 p.

Reference

IEC TS 60076-14:2009

ICS Codes

29.180   Transformers. Reactors

Print number

1 - juin 2009
Sumary
Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials

IEC 60076-14:2009(E) provides specification, design, testing and loading information for use by both the manufacturer and user of liquid-immersed power transformers employing either high-temperature insulation or combinations of high-temperature and conventional insulation. Is applicable to:
- power transformers designed in accordance with IEC 60076-1,
- convertor transformers designed to IEC 61378 series,
- arc furnace transformers,
- and covers the use of various liquid and solid insulation combinations. This new edition includes the following significant technical changes with respect to the previous edition:
- enhancement of insulation system descriptions;
- clarification of temperature rise limits
- and the addition of overload temperature limits.
Replaced standards (1)
IEC TS 60076-14:2004
IEC TS 60076-14:2004
November 2004
Technical specification Cancelled
Power transformers - Part 14: Design and application of liquid-immersed power transformers using high-temperature insulation materials

Provides design, testing and loading information for use by both the manufacturer and user of liquid-immersed power transformers using either high-temperature insulation or combinations of high-temperature and conventional insulation.

Standard replaced by (1)
IEC 60076-14:2013
IEC 60076-14:2013
September 2013
International standard Current
Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials

IEC 60076-14:2013 applies to liquid-immersed power transformers employing either high-temperature insulation or combinations of high-temperature and conventional insulation, operating at temperatures above conventional limits. It is applicable to: - power transformers in accordance with IEC 60076-1; - convertor transformers according to IEC 61378 series; - transformers for wind turbine applications in accordance with IEC 60076-16; - arc furnace transformers; - reactors in accordance with IEC 60076-6. This part of IEC 60076 may be applicable as a reference for the use of high-temperature insulation materials in other types of transformers and reactors. This first edition of IEC 60076-14 cancels and replaces the second edition of the Technical Specification IEC/TS 60076-14 published in 2009. It constitutes a technical revision.