Fire hazard testing - Part 6-30: Smoke obscuration - Small-scale static method - Apparatus

IEC/TS 60695-2-30:2013 describes the apparatus, calibration procedures and basic experimental procedures for the determination of the specific optical density of smoke produced by materials exposed vertically to a radiant heat source with or without the application of a pilot flame. The test specimens are of a defined size. The determination of the optical density is carried out in a pressure-controlled chamber previously calibrated with reference materials. The test methods are only applicable to flat, solid, non-metallic test specimens, of materials used in electrotechnical products. This technical specification does not provide a classification system for the behaviour of materials. The test methods are not applicable for materials that melt and flow away from the direct impingement of heat flux. The test methods are not recommended for further development for electrotechnical products nor are they recommended as the basis for regulation or other controls on smoke release due to the limitations of the physical fire model and the test specimen geometry - see Clause 4. This second edition of IEC/TS 60695-6-30 cancels and replaces the first edition published in 1996. It constitutes a technical revision. The main changes with respect to the previous edition are as follows:- This publication is to be re-designated as a technical specification.- The title has been modified to align with the IEC Directives.- The FOREWORD has been revised and updated.- An INTRODUCTION has been added.- The Scope has been updated.- The normative references have been updated.- The terms and definitions have been updated.- Clause 4: Relevance of test data and special observations has been revised.- Detailed editorial updates have been added throughout the document.It has the status of a basic safety publication in accordance with IEC Guide 104 and ISO/IEC Guide 51.Keywords: Smoke obscuration, Fire Hazard.This publication is to be read in conjunction with IEC 60695-6-31:2013.

Main informations

Collections

International IEC standards

Publication date

April 2013

Number of pages

79 p.

Reference

IEC TS 60695-6-30:2013

Print number

2 - 26/04/2013
Sumary
Fire hazard testing - Part 6-30: Smoke obscuration - Small-scale static method - Apparatus

IEC/TS 60695-2-30:2013 describes the apparatus, calibration procedures and basic experimental procedures for the determination of the specific optical density of smoke produced by materials exposed vertically to a radiant heat source with or without the application of a pilot flame. The test specimens are of a defined size. The determination of the optical density is carried out in a pressure-controlled chamber previously calibrated with reference materials. The test methods are only applicable to flat, solid, non-metallic test specimens, of materials used in electrotechnical products. This technical specification does not provide a classification system for the behaviour of materials. The test methods are not applicable for materials that melt and flow away from the direct impingement of heat flux. The test methods are not recommended for further development for electrotechnical products nor are they recommended as the basis for regulation or other controls on smoke release due to the limitations of the physical fire model and the test specimen geometry - see Clause 4. This second edition of IEC/TS 60695-6-30 cancels and replaces the first edition published in 1996. It constitutes a technical revision. The main changes with respect to the previous edition are as follows:
- This publication is to be re-designated as a technical specification.
- The title has been modified to align with the IEC Directives.
- The FOREWORD has been revised and updated.
- An INTRODUCTION has been added.
- The Scope has been updated.
- The normative references have been updated.
- The terms and definitions have been updated.
- Clause 4: Relevance of test data and special observations has been revised.
- Detailed editorial updates have been added throughout the document.
It has the status of a basic safety publication in accordance with IEC Guide 104 and ISO/IEC Guide 51. Keywords: Smoke obscuration, Fire Hazard.

This publication is to be read in conjunction with IEC 60695-6-31:2013.
Replaced standards (1)
IEC 60695-6-30:1996
October 1996
International standard Cancelled
Fire hazard testing. Part 6 : guidance and test methods on the assessment of obscuration hazard of vision caused by smoke opacity from electrotechnical products involved in fires. Section 30 : small scale static method. Determination of smoke opacity. Description of the apparatus.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ