IEC TS 61233:1994
IEC TS 61233:1994

IEC TS 61233:1994

July 1994
Technical specification Cancelled

High-voltage alternating current circuit-breakers - Inductive load switching

Is applicable to circuit-breakers which are used for switching of: - transformer magnetizing currents, or - currents of high-voltage motors, or - currents of shunt reactors. It is also applicable to contactors used for switching the currents of high-voltage motors.

Main informations

Collections

International IEC standards

Publication date

July 1994

Number of pages

158 p.

Reference

IEC TS 61233:1994

ICS Codes

29.130.10   High voltage switchgear and controlgear

Print number

1
Sumary
High-voltage alternating current circuit-breakers - Inductive load switching

Is applicable to circuit-breakers which are used for switching of: - transformer magnetizing currents, or - currents of high-voltage motors, or - currents of shunt reactors. It is also applicable to contactors used for switching the currents of high-voltage motors.
Standard replaced by (1)
IEC 62271-110:2005
IEC 62271-110:2005
June 2005
International standard Cancelled
High-voltage switchgear and controlgear - Part 110: Inductive load switching

Applicable to a.c. circuit-breakers designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1000 V and applied for inductive current switching with or without additional short-circuit current breaking duties. The standard is applicable to circuit-breakers in accordance with IEC 62271-100 that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents. Switching unloaded transformers, i.e. breaking transformer magnetizing current, is not considered in this standard. The reasons for this are as follows: a) due to the non-linearity of the transformer core, it is not possible to correctly model the switching of transformer magnetizing current using linear components in a test laboratory. Tests conducted using an available transformer, such as a test transformer, will only be valid for the transformer tested and cannot be representative for other transformers; b) as detailed in the guide for application of IEC 62271-100 and IEC 60694, the characteristics of this duty are usually less severe than any other inductive current switching duty. It should be noted that such a duty may produce severe overvoltages within the transformer winding(s) depending on the circuit-breaker re ignition behaviour and transformer winding resonance frequencies. Short-line faults, out-of-phase current making and breaking and capacitive current switching are not applicable to circuit-breakers applied to switch shunt reactors or motors. These duties are therefore not included in this standard.