IEC TS 61587-3:1999
IEC TS 61587-3:1999

IEC TS 61587-3:1999

October 1999
Technical specification Cancelled

Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets, racks and subracks

Specifies the test of empty cabinets and subracks concerning electromagnetic shielding performance, in the frequency range of 30 MHz to 1 000 MHz. Stipulated attenuation values are chosen for the definition of the shielding performance level of cabinets and subracks as per the IEC 60297 and IEC 60917 series. The purpose is to ensure physical integrity and environmental performance in cabinets and subracks.

Main informations

Collections

International IEC standards

Publication date

October 1999

Number of pages

11 p.

Reference

IEC TS 61587-3:1999

Print number

1
Sumary
Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets, racks and subracks

Specifies the test of empty cabinets and subracks concerning electromagnetic shielding performance, in the frequency range of 30 MHz to 1 000 MHz. Stipulated attenuation values are chosen for the definition of the shielding performance level of cabinets and subracks as per the IEC 60297 and IEC 60917 series. The purpose is to ensure physical integrity and environmental performance in cabinets and subracks.
Standard replaced by (1)
IEC 61587-3:2006
IEC 61587-3:2006
June 2006
International standard Cancelled
Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets, racks and subracks

Specifies the tests for empty cabinets and subracks concerning electromagnetic shielding performance, in the frequency range of 30 MHz to 2 000 MHz. Ensures physical integrity and environmental performance of cabinets and subracks, taking into account the need for different levels of performance in different applications. Was developed in close relationship to IEC 61000-5-7 but with the specific focus on subracks and cabinets and the determination of performance levels at the chosen frequency range.