IEC TS 61639:1996
Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above
Applicable to the single-phase connection assemblies between gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above satisfying the requirements of IEC 60517 and power transformers satisfying the requirements of IEC 60076 and fitted with completely immersed bushings satisfying the requirements of IEC 60137, one end of which is immersed in the transformer oil, and the other end in the insulating gas of the switchgear.Its purpose is to establish electrical and mechanical interchangeability in the interface arrangement of these connection assemblies and to determine the limits of supply.
Applicable to the single-phase connection assemblies between gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above satisfying the requirements of IEC 60517 and power transformers satisfying the requirements of IEC 60076 and fitted with completely immersed bushings satisfying the requirements of IEC 60137, one end of which is immersed in the transformer oil, and the other end in the insulating gas of the switchgear. Its purpose is to establish electrical and mechanical interchangeability in the interface arrangement of these connection assemblies and to determine the limits of supply.
IEC 62271-211:2014 is applicable to single and three phase direct connections between gas-insulated metal-enclosed switchgear (GIS) for rated voltages above 52 kV and transformer arrangements to establish electrical and mechanical interchange ability and to determine the limits of supply of for the transformer connection. This first edition cancels and replaces the first edition of IEC TR 61639:1996 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) transfer from technical report to international standard; b) the minimum voltage rating was changed from 72,5 kV to above 52 kV; c) update of normative references; d) definition of insulated junction including limit of supply; e) definition of dielectric test of gas-insulated metal-enclosed switchgear for transformer connection in a three phase enclosure; f) addition of interface tolerances at transformer side; g) addition of transformer tolerances in service; h) addition of exceptional loads for bushings and flanges; i) consideration of oil- and gas-insulated transformers; j) inclusion of three-phase enclosed direct connections. The contents of the corrigendum 1 of August 2015 and corrigendum 2 of August 2017 have been included in this copy.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ