ISO 10927:2018
ISO 10927:2018

ISO 10927:2018

June 2018
International standard Current

Plastics - Determination of the molecular mass and molecular mass distribution of polymer species by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS)

This document specifies a general method for determining the average molecular mass and molecular mass distribution of polymers (see Reference [1]) from 2 000 g ⋅ mol−1 to 20 000 g ⋅ mol−1 by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS).The average molecular masses and molecular mass distributions are calculated from a calibration curve constructed using synthetic-polymer and/or biopolymer standards. This method is therefore classified as a relative method.The method is not applicable to polyolefins or to polymers with a polydispersity >1,2.

View the extract
Main informations

Collections

International ISO standards

Publication date

June 2018

Number of pages

13 p.

Reference

ISO 10927:2018

ICS Codes

83.080.01   Plastics in general

Print number

1
Sumary
Plastics - Determination of the molecular mass and molecular mass distribution of polymer species by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS)

This document specifies a general method for determining the average molecular mass and molecular mass distribution of polymers (see Reference [1]) from 2 000 g ⋅ mol−1 to 20 000 g ⋅ mol−1 by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS).

The average molecular masses and molecular mass distributions are calculated from a calibration curve constructed using synthetic-polymer and/or biopolymer standards. This method is therefore classified as a relative method.

The method is not applicable to polyolefins or to polymers with a polydispersity >1,2.

Replaced standards (1)
ISO 10927:2011
ISO 10927:2011
April 2011
International standard Cancelled
Plastics - Determination of the molecular mass and molecular mass distribution of polymer species by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS)

ISO 10927:2011 specifies a general method for determining the average molecular mass and molecular mass distribution of polymers from 2 000 g.mol-1 to 20 000 g.mol-1 by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI‑TOF‑MS). The average molecular masses and molecular mass distributions are calculated from a calibration curve constructed using synthetic-polymer and/or biopolymer standards. This method is therefore classified as a relative method. The method is not applicable to polyolefins or to polymers with a polydispersity > 1,2.

ZOOM ON ... the Requirements department

To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:

  • mandatory clauses to satisfy,
  • non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document "ISO/IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents" as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!


What is the Redline format?
Need to identify, monitor and decipher standards?