ISO 13571:2012
Life-threatening components of fire - Guidelines for the estimation of time to compromised tenability in fires
ISO 13571:2012 is one of many tools available for use in fire safety engineering. It is intended to be used in conjunction with models for analysis of the initiation and development of fire, fire spread, smoke formation and movement, chemical species generation, transport and decay, and people movement, as well as fire detection and suppression. ISO 13571:2012 is to be used only within this context.ISO 13571:2012 is intended to address the consequences of human exposure to the life-threatening components of fire. The time-dependent concentrations of fire effluents and the thermal environment of a fire are determined by the rate of fire growth, the yields of the various fire gases produced from the involved fuels, the decay characteristics of those fire gases and the ventilation pattern. Once these are determined, the methodology presented in ISO 13571:2012 can be used for the estimation of the time at which individuals can be expected to experience compromised tenability.With care, this guidance can also be applied to estimation of the time limit for rescuing people who are immobile due to injury, medical condition, etc.ISO 13571:2012 establishes procedures to evaluate the life-threatening components of fire hazard analysis in terms of the status of exposed human subjects at discrete time intervals. It makes possible the estimation of the time at which occupants can experience compromised tenability. It enables estimation of a compromised tenability endpoint for each of the fire effluent components, with the most important endpoint being the earliest to occur.Although the concept of compromised tenability is consistent with the definition of incapacitation (see ISO 13943), the latter term is not used in ISO 13571:2012 due to its potentially broad interpretation to include many effects, including collapse and unconsciousness, that are not addressed. ISO 13571:2012 focuses specifically on compromised tenability as influenced by both physiological and behavioural responses resulting from exposure to a fire's life-threatening components.The life-threatening components addressed include fire-effluent toxicity, heat, and visual obscuration due to smoke. In cases where the effluent composition is available, the toxic gas model is to be used for assessment of fire-effluent toxicity. For those cases where the effluent composition is unknown, an additional mass-loss model using generic toxic potency values is provided.
ISO 13571:2012 is one of many tools available for use in fire safety engineering. It is intended to be used in conjunction with models for analysis of the initiation and development of fire, fire spread, smoke formation and movement, chemical species generation, transport and decay, and people movement, as well as fire detection and suppression. ISO 13571:2012 is to be used only within this context.
ISO 13571:2012 is intended to address the consequences of human exposure to the life-threatening components of fire. The time-dependent concentrations of fire effluents and the thermal environment of a fire are determined by the rate of fire growth, the yields of the various fire gases produced from the involved fuels, the decay characteristics of those fire gases and the ventilation pattern. Once these are determined, the methodology presented in ISO 13571:2012 can be used for the estimation of the time at which individuals can be expected to experience compromised tenability.
With care, this guidance can also be applied to estimation of the time limit for rescuing people who are immobile due to injury, medical condition, etc.
ISO 13571:2012 establishes procedures to evaluate the life-threatening components of fire hazard analysis in terms of the status of exposed human subjects at discrete time intervals. It makes possible the estimation of the time at which occupants can experience compromised tenability. It enables estimation of a compromised tenability endpoint for each of the fire effluent components, with the most important endpoint being the earliest to occur.
Although the concept of compromised tenability is consistent with the definition of incapacitation (see ISO 13943), the latter term is not used in ISO 13571:2012 due to its potentially broad interpretation to include many effects, including collapse and unconsciousness, that are not addressed. ISO 13571:2012 focuses specifically on compromised tenability as influenced by both physiological and behavioural responses resulting from exposure to a fire's life-threatening components.
The life-threatening components addressed include fire-effluent toxicity, heat, and visual obscuration due to smoke. In cases where the effluent composition is available, the toxic gas model is to be used for assessment of fire-effluent toxicity. For those cases where the effluent composition is unknown, an additional mass-loss model using generic toxic potency values is provided.
ISO 13571:2007 is only one of many tools available for use in fire safety engineering. It is intended to be used in conjunction with models for analysis of the initiation and development of fire, fire spread, smoke formation and movement, chemical species generation, transport and decay and people movement, as well as fire detection and suppression. ISO 13571:2007 is to be used only within this context. ISO 13571:2007 is intended to address the consequences of human exposure to the life threat components of fire as occupants move through an enclosed structure. The time-dependent concentrations of fire effluents and the thermal environment of a fire are determined by the rate of fire growth, the yields of the various fire gases produced from the involved fuels, the decay characteristics of those fire gases and the ventilation pattern within the structure. Once these are determined, the methodology presented in ISO 13571:2007 can be used for the estimation of the available escape time. ISO 13571:2007 provides guidance on establishing the procedures to evaluate the life threat components of fire hazard analysis in terms of the status of exposed human subjects at discrete time intervals. It makes possible the determination of a tenability endpoint, at which time it is estimated that occupants are no longer able to take effective action to accomplish their own escape. The life threat components addressed include fire-effluent toxicity, heat and visual obscuration due to smoke. Two methods are presented for assessment of fire-effluent toxicity: the toxic-gas model and the mass-loss model. ISO 13571:2007 does not consider aspects such as the initial impact of visual obscuration due to smoke on factors affecting the time required for occupants to escape, the toxic effects of aerosols and particulates and any interactions with gaseous fire-effluent components and adverse health effects following exposure to fire atmospheres.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ