ISO 15042:2017

ISO 15042:2017

July 2017
International standard Current

Multiple split-system air-conditioners and air-to-air heat pumps - Testing and rating for performance

ISO 15042:2017 specifies the performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.ISO 15042:2017 is applicable to the following equipment:-― basic multi-split systems, modular multi-split systems and modular heat recovery multi-split systems. These multi-split systems include air-to-air systems with non-ducted and/or ducted indoor units with integral fans and indoor units supplied without fans.ISO 15042:2017 is limited to:- residential, commercial and industrial split-system air conditioners and heat pumps;- factory-made, electrically driven and use mechanical compression;- single- and multiple-circuit split-systems which utilize one or more compressors with no more than two steps of control of the outdoor unit;or- split-systems with a single refrigeration circuit which utilize one or more variable-speed compressors or alternative compressor combinations for varying the capacity of the system by three or more steps.These split-systems are designed to operate with a combination of one or more outdoor units and two or more indoor units designed for individual operation, and such modular systems are capable of transferring recovered heat from one or more indoor units to other units in the same system.The requirements of testing and rating contained in this document are based on the use of matched assemblies.ISO 15042:2017 is not applicable to the rating and testing of the following:a) water-cooled or water source equipment;b) mobile (single-duct) units having a condenser exhaust duct;c) individual assemblies not constituting a complete refrigeration system;d) equipment using the absorption refrigeration cycle.e) ducted air conditioners and/or ducted heat pumps, rated at less than 8 kW and intended to operate at external static pressures of less than 25 Pa, controlled by a single thermostat/controller (refer to ISO 5151);f) multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller (refer to ISO 5151 or ISO 13253).ISO 15042:2017 does not cover the determination of seasonal efficiencies or seasonal part-load performances, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.NOTE Throughout this document, the terms "equipment" and "systems" mean "multi-split air conditioners" and/or "multi-split heat pumps".

View the extract
Main informations

Collections

International ISO standards

Publication date

July 2017

Number of pages

97 p.

Reference

ISO 15042:2017

ICS Codes

23.120   Ventilators. Fans. Air-conditioners
27.080   Heat pumps

Print number

1
Sumary
Multiple split-system air-conditioners and air-to-air heat pumps - Testing and rating for performance

ISO 15042:2017 specifies the performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.

ISO 15042:2017 is applicable to the following equipment:

-― basic multi-split systems, modular multi-split systems and modular heat recovery multi-split systems. These multi-split systems include air-to-air systems with non-ducted and/or ducted indoor units with integral fans and indoor units supplied without fans.

ISO 15042:2017 is limited to:

- residential, commercial and industrial split-system air conditioners and heat pumps;

- factory-made, electrically driven and use mechanical compression;

- single- and multiple-circuit split-systems which utilize one or more compressors with no more than two steps of control of the outdoor unit;

or

- split-systems with a single refrigeration circuit which utilize one or more variable-speed compressors or alternative compressor combinations for varying the capacity of the system by three or more steps.

These split-systems are designed to operate with a combination of one or more outdoor units and two or more indoor units designed for individual operation, and such modular systems are capable of transferring recovered heat from one or more indoor units to other units in the same system.

The requirements of testing and rating contained in this document are based on the use of matched assemblies.

ISO 15042:2017 is not applicable to the rating and testing of the following:

a) water-cooled or water source equipment;

b) mobile (single-duct) units having a condenser exhaust duct;

c) individual assemblies not constituting a complete refrigeration system;

d) equipment using the absorption refrigeration cycle.

e) ducted air conditioners and/or ducted heat pumps, rated at less than 8 kW and intended to operate at external static pressures of less than 25 Pa, controlled by a single thermostat/controller (refer to ISO 5151);

f) multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller (refer to ISO 5151 or ISO 13253).

ISO 15042:2017 does not cover the determination of seasonal efficiencies or seasonal part-load performances, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

NOTE Throughout this document, the terms "equipment" and "systems" mean "multi-split air conditioners" and/or "multi-split heat pumps".

Replaced standards (1)
ISO 15042:2011
November 2011
International standard Cancelled
Multiple split-system air-conditioners and air-to-air heat pumps - Testing and rating for performance

ISO 15042:2011 establishes performance testing and rating criteria for factory-made residential, commercial and industrial, electrically-driven, mechanical-compression, air-cooled air-conditioners and air-to-air heat pumps, described as basic multi-split systems, modular multi-split systems and modular heat recovery multi-split systems. These multi-split systems include air-to-air systems with non-ducted and/or ducted indoor units with integral fans and indoor units supplied without fans. ISO 15042:2011 is limited to single and multiple circuit split-systems which utilize one or more compressors with no more than two steps of control of the outdoor unit. It is also limited to split-systems with a single refrigeration circuit which utilize one or more variable-speed compressors or alternative compressor combinations for varying the capacity of the system by three or more steps. These split-systems are designed to operate with a combination of one or more outdoor units and two or more indoor units designed for individual operation, and such modular systems that are capable of transferring recovered heat from one or more indoor units to other units in the same system.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
What is the Redline format?
The Redline + service - standards comparator allows you to easily and simply identify major changes between the current standard and its last canceled version.

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.

For an overview of the service, click on View a standard in redline format
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ