ISO 16422-5:2024
Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure - Part 5: Fitness for purpose of the system
This document specifies the characteristics of the fitness for purpose of oriented unplasticized poly(vinyl chloride) (PVC-O) solid wall piping intended to be used underground or above-ground where protected from direct sunlight, for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. It also specifies the test parameters for the test methods referred to in this document.This document is not intended for on-site testing of pipe systems.In conjunction with ISO 16422-1, ISO 16422-2, ISO/TS 16422-3 and ISO 1452-3, this document is applicable to PVC-O pipes and PVC-O fittings, as well as to their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following:a) water mains and services lines;b) conveyance of water for both outside and inside buildings;c) drainage, sewerage and treated wastewater under pressure;d) irrigation under pressure.This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure. This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see ISO 16422-2:2023, Figure C.1.The piping system according to this document is intended for the conveyance of cold water up to pressures of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar.[1] 1 bar= 0,1 MPa = 105 Pa; 1 MPa= 1 N/mm2
This document specifies the characteristics of the fitness for purpose of oriented unplasticized poly(vinyl chloride) (PVC-O) solid wall piping intended to be used underground or above-ground where protected from direct sunlight, for water supply, buried drainage, sewerage, treated wastewater and irrigation under pressure. It also specifies the test parameters for the test methods referred to in this document.
This document is not intended for on-site testing of pipe systems.
In conjunction with ISO 16422-1, ISO 16422-2, ISO/TS 16422-3 and ISO 1452-3, this document is applicable to PVC-O pipes and PVC-O fittings, as well as to their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following:
a) water mains and services lines;
b) conveyance of water for both outside and inside buildings;
c) drainage, sewerage and treated wastewater under pressure;
d) irrigation under pressure.
This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for wastewater under pressure.
This document is also applicable to components for the conveyance of water and wastewater up to and including 45 °C. For temperatures between 25 °C and 45 °C, see ISO 16422-2:2023, Figure C.1.
The piping system according to this document is intended for the conveyance of cold water up to pressures of 25 bar[1] and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bar.
[1] 1 bar= 0,1 MPa = 105 Pa; 1 MPa= 1 N/mm2
ISO 16422:2014 specifies the requirements of pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O), for piping systems intended to be used underground or above-ground where not exposed to direct sunlight, for water mains and services, pressurized sewer systems and irrigation systems. The piping system according to ISO 16422:2014 is intended for the conveyance of cold water under pressure, for drinking water and for general purposes up to and including 45 °C, and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations, up to pressure of 25 bars[1]. Joints constructed of other materials should meet their own relevant standards in addition to the fitness-for-purpose requirements of ISO 16422:2014. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ