ISO 21438-1:2022
Workplace atmospheres - Determination of inorganic acids by ion chromatography - Part 1: Non-volatile acids (sulfuric acid and phosphoric acid)
This document specifies a method for the determination of the time-weighted average mass concentration of sulfuric acid and phosphoric acid in workplace air by ion chromatography. The anions are detected by conductivity.The method is applicable to the personal sampling of airborne particles, as defined in ISO 7708, and to static (area) sampling.The method does not apply to the determination of sulfur trioxide.The procedure does not differentiate between the acids and their corresponding salts if both are present in the workplace air.The procedure does not differentiate between phosphoric acid and diphosphorus pentoxide (phosphoric anhydride) if both are present in the workplace air.
This document specifies a method for the determination of the time-weighted average mass concentration of sulfuric acid and phosphoric acid in workplace air by ion chromatography. The anions are detected by conductivity.
The method is applicable to the personal sampling of airborne particles, as defined in ISO 7708, and to static (area) sampling.
The method does not apply to the determination of sulfur trioxide.
The procedure does not differentiate between the acids and their corresponding salts if both are present in the workplace air.
The procedure does not differentiate between phosphoric acid and diphosphorus pentoxide (phosphoric anhydride) if both are present in the workplace air.
ISO 21438-1:2007 specifies a method for the determination of the time-weighted average mass concentration of sulfuric acid and phosphoric acid in workplace air by ion chromatography. The method is applicable to the personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708 and to static (area) sampling. The analytical method is applicable to the determination of masses of 0,005 mg to 2,000 mg of sulfuric acid and phosphoric acid per sample, without dilution. The concentration range of sulfuric acid and phosphoric acid in air for which the measuring procedure is applicable is determined by the sampling method selected by the user. For an air sample of volume 1 m3, the working range is approximately 0,005 mg/m3 to 2,000 mg/m3. The method is not applicable to the determination of sulfur trioxide. The procedure does not allow differentiation between the acids and their corresponding salts if both are present in the air. The procedure does not allow differentiation between phosphoric acid and diphosphorus pentoxide (phosphoric anhydride) if both are present in the workplace.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ