ISO 21501-4:2018

ISO 21501-4:2018

May 2018
International standard Current

Determination of particle size distribution - Single particle light interaction methods - Part 4: Light scattering airborne particle counter for clean spaces

This document describes a calibration and verification method for a light scattering airborne particle counter (LSAPC), which is used to measure the size distribution and particle number concentration of particles suspended in air. The light scattering method described in this document is based on single particle measurements. The typical size range of particles measured by this method is between 0,1 μm and 10 μm in particle size.Instruments that conform to this document are used for the classification of air cleanliness in cleanrooms and associated controlled environments in accordance with ISO 14644‑1 and ISO 14644‑2, as well as the measurement of number and size distribution of particles in various environments.The following parameters are within the scope of this document:— size setting error;— counting efficiency;— size resolution;— false count;— maximum particle number concentration;— sampling flow rate error;— sampling time error;— response rate;— calibration interval;— reporting results from test and calibration.

View the extract
Main informations

Collections

International ISO standards

Publication date

May 2018

Number of pages

25 p.

Reference

ISO 21501-4:2018

ICS Codes

19.120   Particle size analysis. Sieving

Print number

1
Sumary
Determination of particle size distribution - Single particle light interaction methods - Part 4: Light scattering airborne particle counter for clean spaces

This document describes a calibration and verification method for a light scattering airborne particle counter (LSAPC), which is used to measure the size distribution and particle number concentration of particles suspended in air. The light scattering method described in this document is based on single particle measurements. The typical size range of particles measured by this method is between 0,1 μm and 10 μm in particle size.

Instruments that conform to this document are used for the classification of air cleanliness in cleanrooms and associated controlled environments in accordance with ISO 14644‑1 and ISO 14644‑2, as well as the measurement of number and size distribution of particles in various environments.

The following parameters are within the scope of this document:

— size setting error;

— counting efficiency;

— size resolution;

— false count;

— maximum particle number concentration;

— sampling flow rate error;

— sampling time error;

— response rate;

— calibration interval;

— reporting results from test and calibration.

Replaced standards (1)
ISO 21501-4:2007
May 2007
International standard Cancelled
Determination of particle size distribution - Single particle light interaction methods - Part 4 : light scattering airborne particle counter for clean spaces

ISO 21501-4:2007 describes a calibration and verification method for a light scattering airborne particle counter (LSAPC), which is used to measure the size and particle number concentration of particles suspended in air. The light scattering method described in ISO 21501-4:2007 is based on single particle measurements. The typical size range of particles measured by this method is between 0,1 µm and 10 µm in particle size. Instruments that conform to ISO 21501-4:2007 are used for the classification of air cleanliness in cleanrooms and associated controlled environments in accordance with ISO 14644-1, as well as the measurement of number and size distribution of particles in various environments. The following are within the scope of ISO 21501-4:2007: size calibration;verification of size setting;counting efficiency;size resolution;false count rate;maximum particle number concentration;sampling flow rate;sampling time;sampling volume;calibration interval;test report.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
What is the Redline format?
The Redline + service - standards comparator allows you to easily and simply identify major changes between the current standard and its last canceled version.

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.

For an overview of the service, click on View a standard in redline format
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ