ISO 23655-2:2022

ISO 23655-2:2022

September 2022
International standard Current

Water quality - Nickel-59 and nickel-63 - Part 2: Test method using ICP-MS

This document specifies the determination of nickel-59 and nickel-63 (59Ni and 63Ni) activity concentration in samples of all types of water using inductively coupled plasma mass spectrometry (ICP-MS).Using currently available ICP-MS, this test method can measure 59Ni activity concentrations of 300 mBq⋅l−1 and 63Ni activity concentrations of 200 Bq⋅l−1. These values can be achieved with a sample volume of 1,0 l. Higher activity concentrations can be measured by either diluting the sample or using smaller sample aliquots or both.NOTE       These performance indicators are wholly dependent on the measurement regimes in individual laboratories; in particular, the detection limit is influenced by amount of stable nickel present.The range of application depends on the amount of dissolved material in the water and on the performance characteristics of the measurement equipment (background count rate and counting efficiency).It is the laboratory’s responsibility to ensure the suitability of this test method for the water samples tested.

View the extract
Main informations

Collections

International ISO standards

Publication date

September 2022

Number of pages

16 p.

Reference

ISO 23655-2:2022

ICS Codes

13.060.60   Examination of physical properties of water
17.240   Radiation measurements

Print number

1
Sumary
Water quality - Nickel-59 and nickel-63 - Part 2: Test method using ICP-MS

This document specifies the determination of nickel-59 and nickel-63 (59Ni and 63Ni) activity concentration in samples of all types of water using inductively coupled plasma mass spectrometry (ICP-MS).

Using currently available ICP-MS, this test method can measure 59Ni activity concentrations of 300 mBq⋅l−1 and 63Ni activity concentrations of 200 Bq⋅l−1. These values can be achieved with a sample volume of 1,0 l. Higher activity concentrations can be measured by either diluting the sample or using smaller sample aliquots or both.

NOTE       These performance indicators are wholly dependent on the measurement regimes in individual laboratories; in particular, the detection limit is influenced by amount of stable nickel present.

The range of application depends on the amount of dissolved material in the water and on the performance characteristics of the measurement equipment (background count rate and counting efficiency).

It is the laboratory’s responsibility to ensure the suitability of this test method for the water samples tested.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ