ISO 26802:2010

ISO 26802:2010

August 2010
International standard Current

Nuclear facilities - Criteria for the design and the operation of containment and ventilation systems for nuclear reactors

ISO 26802:2010 specifies the applicable requirements related to the design and the operation of containment and ventilation systems of nuclear power plants and research reactors taking into account the following.For nuclear power plants, ISO 26802:2010 addresses only reactors that have a secondary confinement system based on IAEA recommendations.For research reactors, ISO 26802:2010 applies specifically to reactors for which accidental situations can challenge the integrity or leak-tightness of the containment barrier, i.e. in which a high-pressure or -temperature transient can occur and for which the isolation of the containment building and the shut-off of the associated ventilation systems of the containment building is required.The requirements of ISO 26802:2010 apply to research reactors in which the increase of pressure or temperature during accidental situations do not risk damaging the ventilation systems, although the requirements applicable for the design and the use of ventilation systems are given in ISO 17873.

View the extract
Main informations

Collections

International ISO standards

Publication date

August 2010

Number of pages

84 p.

Reference

ISO 26802:2010

ICS Codes

27.120.10   Reactor engineering

Print number

1 - 27/07/2010
Sumary
Nuclear facilities - Criteria for the design and the operation of containment and ventilation systems for nuclear reactors

ISO 26802:2010 specifies the applicable requirements related to the design and the operation of containment and ventilation systems of nuclear power plants and research reactors taking into account the following.

For nuclear power plants, ISO 26802:2010 addresses only reactors that have a secondary confinement system based on IAEA recommendations.

For research reactors, ISO 26802:2010 applies specifically to reactors for which accidental situations can challenge the integrity or leak-tightness of the containment barrier, i.e. in which a high-pressure or -temperature transient can occur and for which the isolation of the containment building and the shut-off of the associated ventilation systems of the containment building is required.

The requirements of ISO 26802:2010 apply to research reactors in which the increase of pressure or temperature during accidental situations do not risk damaging the ventilation systems, although the requirements applicable for the design and the use of ventilation systems are given in ISO 17873.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ