Nuclear facilities — Criteria for the design and the operation of containment and ventilation systems for nuclear reactors

ISO 26802:2010 specifies the applicable requirements related to the design and the operation of containment and ventilation systems of nuclear power plants and research reactors taking into account the following.For nuclear power plants, ISO 26802:2010 addresses only reactors that have a secondary confinement system based on IAEA recommendations.For research reactors, ISO 26802:2010 applies specifically to reactors for which accidental situations can challenge the integrity or leak-tightness of the containment barrier, i.e. in which a high-pressure or -temperature transient can occur and for which the isolation of the containment building and the shut-off of the associated ventilation systems of the containment building is required.The requirements of ISO 26802:2010 apply to research reactors in which the increase of pressure or temperature during accidental situations do not risk damaging the ventilation systems, although the requirements applicable for the design and the use of ventilation systems are given in ISO 17873.

View the extract
Main informations

Collections

International ISO standards

Publication date

July 2010

Number of pages

87 p.

Reference

ISO 26802:2010

ICS Codes

27.120.10   Reactor engineering

Print number

1 - juillet 2010
Sumary
Nuclear facilities — Criteria for the design and the operation of containment and ventilation systems for nuclear reactors

ISO 26802:2010 specifies the applicable requirements related to the design and the operation of containment and ventilation systems of nuclear power plants and research reactors taking into account the following.

For nuclear power plants, ISO 26802:2010 addresses only reactors that have a secondary confinement system based on IAEA recommendations.

For research reactors, ISO 26802:2010 applies specifically to reactors for which accidental situations can challenge the integrity or leak-tightness of the containment barrier, i.e. in which a high-pressure or -temperature transient can occur and for which the isolation of the containment building and the shut-off of the associated ventilation systems of the containment building is required.

The requirements of ISO 26802:2010 apply to research reactors in which the increase of pressure or temperature during accidental situations do not risk damaging the ventilation systems, although the requirements applicable for the design and the use of ventilation systems are given in ISO 17873.