ISO 3747:2010

ISO 3747:2010

December 2010
International standard Current

Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering/survey methods for use in situ in a reverberant environment

ISO 3747:2010 specifies a method for determining the sound power level or sound energy level of a noise source by comparing measured sound pressure levels emitted by a noise source (machinery or equipment) mounted in situ in a reverberant environment, with those from a calibrated reference sound source. The sound power level (or, in the case of noise bursts or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width one octave, is calculated using those measurements. The sound power level or sound energy level with frequency A-weighting applied is calculated using the octave-band levels. The method specified in ISO 3747:2010 is suitable for all types of noise (steady, non-steady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001. The method is primarily applicable to sources which emit broad-band noise. It can, however, also be used for sources which emit narrow-band noise or discrete tones, although there is a possiblity that the measurement reproducibility is then degraded. The noise source under test can be a device, machine, component or sub-assembly, especially one which is non-movable. The test environment that is applicable for measurements made in accordance with ISO 3747:2010 is a room where the sound pressure level at the microphone positions depends mainly on reflections from the room surfaces. In measurements of ISO 12001:1996, accuracy grade 2 (engineering grade), background noise in the test environment is low compared to that of the noise source or reference sound source. Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with ISO 3747:2010, for measurements made in octave bands and for A-weighted frequency calculations performed on them. The reproducibility conforms with that of either ISO 12001:1996, accuracy grade 2 (engineering grade) or ISO 12001:1996, accuracy grade 3 (survey grade), depending on the extent to which the requirements concerning the test environment are met.

View the extract
Main informations

Collections

International ISO standards

Publication date

December 2010

Number of pages

43 p.

Reference

ISO 3747:2010

ICS Codes

17.140.01   Acoustic measurements and noise abatement in general

Print number

1 - 09/12/2010
Sumary
Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering/survey methods for use in situ in a reverberant environment

ISO 3747:2010 specifies a method for determining the sound power level or sound energy level of a noise source by comparing measured sound pressure levels emitted by a noise source (machinery or equipment) mounted in situ in a reverberant environment, with those from a calibrated reference sound source. The sound power level (or, in the case of noise bursts or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width one octave, is calculated using those measurements. The sound power level or sound energy level with frequency A-weighting applied is calculated using the octave-band levels.

The method specified in ISO 3747:2010 is suitable for all types of noise (steady, non-steady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001. The method is primarily applicable to sources which emit broad-band noise. It can, however, also be used for sources which emit narrow-band noise or discrete tones, although there is a possiblity that the measurement reproducibility is then degraded.

The noise source under test can be a device, machine, component or sub-assembly, especially one which is non-movable.

The test environment that is applicable for measurements made in accordance with ISO 3747:2010 is a room where the sound pressure level at the microphone positions depends mainly on reflections from the room surfaces. In measurements of ISO 12001:1996, accuracy grade 2 (engineering grade), background noise in the test environment is low compared to that of the noise source or reference sound source.

Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with ISO 3747:2010, for measurements made in octave bands and for A-weighted frequency calculations performed on them. The reproducibility conforms with that of either ISO 12001:1996, accuracy grade 2 (engineering grade) or ISO 12001:1996, accuracy grade 3 (survey grade), depending on the extent to which the requirements concerning the test environment are met.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ