ISO 5151:2017

ISO 5151:2017

July 2017
International standard Current

Non-ducted air conditioners and heat pumps - Testing and rating for performance

ISO 5151:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.ISO 5151:2017 is applicable to the following equipment:- non-ducted air-cooled air conditioners and non-ducted air-to-air heat pumps; or- ducted air conditioners and/or ducted heat pumps rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa.ISO 5151:2017 is limited to:- residential, commercial and industrial single-package and split-system air conditioners and heat pumps;- factory-made, electrically driven and use mechanical compression;- utilizing single, multiple and variable capacity components;- multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.The requirements of testing and rating contained in this document are based on the use of matched assemblies.ISO 5151:2017 is not applicable to the rating and testing of the following:a) water-source heat pumps or water cooled air conditioners;b) multi-split-system air conditioners and air-to-air heat pumps (follow ISO 15042 for the testing of such equipment);c) mobile (windowless) units having a condenser exhaust duct;d) individual assemblies not constituting a complete refrigeration system;e) equipment using the absorption refrigeration cycle;f) ducted equipment except for those specified in this clause (follow ISO 13253 for the testing of such equipment).ISO 5151:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.NOTE Throughout this document, the terms "equipment" and "systems" mean "air conditioners" and/or "heat pumps".

View the extract
Main informations

Collections

International ISO standards

Publication date

July 2017

Number of pages

74 p.

Reference

ISO 5151:2017

ICS Codes

23.120   Ventilators. Fans. Air-conditioners
27.080   Heat pumps

Print number

1
Sumary
Non-ducted air conditioners and heat pumps - Testing and rating for performance

ISO 5151:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.

ISO 5151:2017 is applicable to the following equipment:

- non-ducted air-cooled air conditioners and non-ducted air-to-air heat pumps; or

- ducted air conditioners and/or ducted heat pumps rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa.

ISO 5151:2017 is limited to:

- residential, commercial and industrial single-package and split-system air conditioners and heat pumps;

- factory-made, electrically driven and use mechanical compression;

- utilizing single, multiple and variable capacity components;

- multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.

The requirements of testing and rating contained in this document are based on the use of matched assemblies.

ISO 5151:2017 is not applicable to the rating and testing of the following:

a) water-source heat pumps or water cooled air conditioners;

b) multi-split-system air conditioners and air-to-air heat pumps (follow ISO 15042 for the testing of such equipment);

c) mobile (windowless) units having a condenser exhaust duct;

d) individual assemblies not constituting a complete refrigeration system;

e) equipment using the absorption refrigeration cycle;

f) ducted equipment except for those specified in this clause (follow ISO 13253 for the testing of such equipment).

ISO 5151:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

NOTE Throughout this document, the terms "equipment" and "systems" mean "air conditioners" and/or "heat pumps".

Replaced standards (1)
ISO 5151:2010
June 2010
International standard Cancelled
Non-ducted air conditioners and heat pumps - Testing and rating for performance

ISO 5151:2010 specifies the standard conditions for capacity and efficiency ratings of non-ducted air-cooled air conditioners and non-ducted air to air heat pumps. It is applicable to ducted units rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa. ISO 5151:2010 also specifies the test methods for determining the capacity and efficiency ratings.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ