ISO 532-1:2017
Acoustics - Methods for calculating loudness - Part 1: Zwicker method
ISO 532-1:2017 specifies two methods for estimating the loudness and loudness level of sounds as perceived by otologically normal persons under specific listening conditions. The first method is intended for stationary sounds and the second method for arbitrary non-stationary (time-varying) sounds, including stationary sounds as a special case.The methods can be applied to any sound recorded as single-channel measurements using a microphone, or as multi-channel measurements, for example by means of a head and torso simulator (see Annex D). Since most important technical sounds are time-varying, a model of time-varying loudness is preferable.The methods are based on the Zwicker algorithm.[14] The method for stationary sounds is provided for reasons of continuity and also offers the use of measured one-third-octave-band levels as input. The more general method for arbitrary sounds calculates the specific loudness pattern based on measured time signals by applying a signal processing model that is directly related to physiological and psychological characteristics of the human hearing system. Loudness is calculated from the specific loudness pattern. It has been shown that this method provides a good match to the results of many loudness experiments using synthetic and technical sounds.No prior knowledge about the properties of the sound (e.g. broadband or narrowband noise, tonal content) and no user interactions are required for the fully automated application of the method.The evaluation of the harmful effect of sound events is outside the scope of ISO 532-1:2017.
ISO 532-1:2017 specifies two methods for estimating the loudness and loudness level of sounds as perceived by otologically normal persons under specific listening conditions. The first method is intended for stationary sounds and the second method for arbitrary non-stationary (time-varying) sounds, including stationary sounds as a special case.
The methods can be applied to any sound recorded as single-channel measurements using a microphone, or as multi-channel measurements, for example by means of a head and torso simulator (see Annex D). Since most important technical sounds are time-varying, a model of time-varying loudness is preferable.
The methods are based on the Zwicker algorithm.[14] The method for stationary sounds is provided for reasons of continuity and also offers the use of measured one-third-octave-band levels as input. The more general method for arbitrary sounds calculates the specific loudness pattern based on measured time signals by applying a signal processing model that is directly related to physiological and psychological characteristics of the human hearing system. Loudness is calculated from the specific loudness pattern. It has been shown that this method provides a good match to the results of many loudness experiments using synthetic and technical sounds.
No prior knowledge about the properties of the sound (e.g. broadband or narrowband noise, tonal content) and no user interactions are required for the fully automated application of the method.
The evaluation of the harmful effect of sound events is outside the scope of ISO 532-1:2017.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ