ISO 5725-3:2023

ISO 5725-3:2023

June 2023
International standard Current

Accuracy (trueness and precision) of measurement methods and results - Part 3: Intermediate precision and alternative designs for collaborative studies

This document providesa)    a discussion of alternative experimental designs for the determination of trueness and precision measures including reproducibility, repeatability and selected measures of intermediate precision of a standard measurement method, including a review of the circumstances in which their use is necessary or beneficial, and guidance as to the interpretation and application of the resulting estimates, andb)    worked examples including specific designs and computations.Each of the alternative designs discussed in this document is intended to address one (or several) of the following issues:a)    a discussion of the implications of the definitions of intermediate precision measures;b)    a guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations;c)    determining reproducibility, repeatability and selected measures of intermediate precision;d)    improved determination of reproducibility and other measures of precision;e)    improving the estimate of the sample mean;f)     determining the range of in-house repeatability standard deviations;g)    determining other precision components such as operator variability;h)    determining the level of reliability of precision estimates;i)     reducing the minimum number of participating laboratories by optimizing the reliability of precision estimates;j)     avoiding distorted estimations of repeatability (split-level designs);k)    avoiding distorted estimations of reproducibility (taking the heterogeneity of the material into consideration).Often, the performance of the method whose precision is being evaluated in a collaborative study will have previously been assessed in a single-laboratory validation study conducted by the laboratory which developed it. Relevant factors for the determination of intermediary precision will have been identified in this prior single-laboratory study.

View the extract
Main informations

Collections

International ISO standards

Publication date

June 2023

Number of pages

57 p.

Reference

ISO 5725-3:2023

ICS Codes

03.120.30   Application of statistical methods
17.020   Metrology and measurement in general

Print number

1
Sumary
Accuracy (trueness and precision) of measurement methods and results - Part 3: Intermediate precision and alternative designs for collaborative studies

This document provides

a)    a discussion of alternative experimental designs for the determination of trueness and precision measures including reproducibility, repeatability and selected measures of intermediate precision of a standard measurement method, including a review of the circumstances in which their use is necessary or beneficial, and guidance as to the interpretation and application of the resulting estimates, and

b)    worked examples including specific designs and computations.

Each of the alternative designs discussed in this document is intended to address one (or several) of the following issues:

a)    a discussion of the implications of the definitions of intermediate precision measures;

b)    a guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations;

c)    determining reproducibility, repeatability and selected measures of intermediate precision;

d)    improved determination of reproducibility and other measures of precision;

e)    improving the estimate of the sample mean;

f)     determining the range of in-house repeatability standard deviations;

g)    determining other precision components such as operator variability;

h)    determining the level of reliability of precision estimates;

i)     reducing the minimum number of participating laboratories by optimizing the reliability of precision estimates;

j)     avoiding distorted estimations of repeatability (split-level designs);

k)    avoiding distorted estimations of reproducibility (taking the heterogeneity of the material into consideration).

Often, the performance of the method whose precision is being evaluated in a collaborative study will have previously been assessed in a single-laboratory validation study conducted by the laboratory which developed it. Relevant factors for the determination of intermediary precision will have been identified in this prior single-laboratory study.

Replaced standards (2)
ISO 5725-3:1994
December 1994
International standard Cancelled
Accuracy (trueness and precision) of measurement methods and results. Part 3 : intermediate measures of the precision of A standard measurement method.

ISO 5725-3/AC1:2001
October 2001
International standard Cancelled
Rectificatif technique 1 à la norme ISO 5725-3 de décembre 1994

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ