Nuclear fuel technology - Determination of uranium in solutions, uranium hexafluoride and solids - Part 2: Iron(II) reduction/cerium(IV) oxidation titrimetric method

This document describes an analytical method for the determination of uranium in samples from pure product materials such as U metal, UO2, UO3, U3O8, uranyl nitrate hexahydrate and uranium hexafluoride from the nuclear fuel cycle. This procedure is sufficiently accurate and precise to be used for nuclear materials accountability. This method can be used directly for the analysis of most uranium and uranium oxide nuclear reactor fuels, either irradiated or un-irradiated, and of uranium nitrate product solutions. Fission products equivalent to up to 10 % burn-up of heavy atoms do not interfere, and other elements which could cause interference are not normally present in sufficient quantity to affect the result significantly. The method recommends that an aliquot of sample is weighed and that a mass titration is used, in order to obtain improved precision and accuracy. This does not preclude the use of alternative techniques which could give equivalent performance. The use of automatic device(s) in the performance of some critical steps of the method has some advantages, mainly in the case of routine analysis.This method does not generate a toxic mixed waste as does the potassium dichromate titration in ISO 7097-1.

Main informations

Collections

International ISO standards

Publication date

November 2022

Reference

ISO 7097-2:2022

ICS Codes

27.120.30   Fissile materials and nuclear fuel technology
Sumary
Nuclear fuel technology - Determination of uranium in solutions, uranium hexafluoride and solids - Part 2: Iron(II) reduction/cerium(IV) oxidation titrimetric method

This document describes an analytical method for the determination of uranium in samples from pure product materials such as U metal, UO2, UO3, U3O8, uranyl nitrate hexahydrate and uranium hexafluoride from the nuclear fuel cycle. This procedure is sufficiently accurate and precise to be used for nuclear materials accountability. This method can be used directly for the analysis of most uranium and uranium oxide nuclear reactor fuels, either irradiated or un-irradiated, and of uranium nitrate product solutions. Fission products equivalent to up to 10 % burn-up of heavy atoms do not interfere, and other elements which could cause interference are not normally present in sufficient quantity to affect the result significantly. The method recommends that an aliquot of sample is weighed and that a mass titration is used, in order to obtain improved precision and accuracy. This does not preclude the use of alternative techniques which could give equivalent performance. The use of automatic device(s) in the performance of some critical steps of the method has some advantages, mainly in the case of routine analysis.

This method does not generate a toxic mixed waste as does the potassium dichromate titration in ISO 7097-1.

Replaced standards (1)
ISO 7097-2:2004
ISO 7097-2:2004
July 2004
International standard Cancelled
Nuclear fuel technology - Determination of uranium in solutions, uranium hexafluoride and solids - Part 2 : iron (II) reduction/cerium (IV) oxidation titrimetric method

ISO 7097:Part 2 describes an analytical method for the determination of uranium in pure product material samples such as U metal, UO2, UO3, uranyl nitrate hexahydrate, uranium hexafluoride and U3O8 from the nuclear fuel cycle. This procedure is sufficiently accurate and precise to be used for nuclear materials accountability. This method does not generate a toxic mixed waste as does the potassium dichromate titration. The method may not be applied to scrap or waste samples until such time as it is qualified by obtaining results statistically equivalent to those obtained by the potassium dichromate method on the same sample types. The method recommends that an aliquot of sample is weighed and that a mass titration is used, in order to obtain improved precision and accuracy. This does not preclude the use of any alternative techniques which could give equivalent performance. As the performance of some steps of the method is critical, the use of some automatic device has some advantages, mainly in the case of routine analysis.

Need to identify, monitor and decipher standards?