ISO 7503-3:2016
Measurement of radioactivity - Measurement and evaluation of surface contamination - Part 3 : apparatus calibration
ISO 7503 and ISO 8769 are addressed to the people responsible for determining the radioactivity present on solid surfaces.ISO 7503-3:2016 applies to the evaluation of contamination on surfaces in terms of activity per unit area by direct and indirect methods of measurement and deals with the complex aspects of instrument calibration.ISO 7503-3:2016 is applicable to well-defined surfaces, such as those of equipment and facilities, containers of radioactive materials, sealed sources, and buildings or land.ISO 7503-3:2016 can be used for laboratory and equipment/installation control and for remediation and monitoring activities to comply with release criteria.This part of ISO 7503 also refers to the following:- calibration laboratories or institutions dealing with radionuclides with complex emission characteristics or radionuclides for which no reference calibration sources are available;- institutions confronted with the task to evaluate surface contaminations consisting of a radionuclide mixture;- institutions/authorities controlling nuclear material transports or material/equipment clearance according to national legislation guideline values or international convention limits.ISO 7503-3:2016 does not apply to contamination of the skin, clothing, or loose material, such as gravel.NOTE Direct evaluation of surface contamination from alpha-emitters, beta-emitters and photon emitters is dealt with in ISO 7503‑1. The test method using wipe-test samples for the evaluation of radioactive surface contaminations is dealt with in ISO 7503‑2.
ISO 7503 and ISO 8769 are addressed to the people responsible for determining the radioactivity present on solid surfaces.
ISO 7503-3:2016 applies to the evaluation of contamination on surfaces in terms of activity per unit area by direct and indirect methods of measurement and deals with the complex aspects of instrument calibration.
ISO 7503-3:2016 is applicable to well-defined surfaces, such as those of equipment and facilities, containers of radioactive materials, sealed sources, and buildings or land.
ISO 7503-3:2016 can be used for laboratory and equipment/installation control and for remediation and monitoring activities to comply with release criteria.
This part of ISO 7503 also refers to the following:
- calibration laboratories or institutions dealing with radionuclides with complex emission characteristics or radionuclides for which no reference calibration sources are available;
- institutions confronted with the task to evaluate surface contaminations consisting of a radionuclide mixture;
- institutions/authorities controlling nuclear material transports or material/equipment clearance according to national legislation guideline values or international convention limits.
ISO 7503-3:2016 does not apply to contamination of the skin, clothing, or loose material, such as gravel.
NOTE Direct evaluation of surface contamination from alpha-emitters, beta-emitters and photon emitters is dealt with in ISO 7503‑1. The test method using wipe-test samples for the evaluation of radioactive surface contaminations is dealt with in ISO 7503‑2.
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ