ISO 7637-3:2016
Road vehicles - Electrical disturbances from conduction and coupling - Part 3 : electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 7637-3:2016 defines bench test methods to evaluate the immunity of devices under test (DUTs) to transient pulses coupled to lines other than supply lines. The test pulses simulate both fast and slow transient disturbances caused by the switching of inductive loads and relay contact bounce. The following three test methods are described in ISO 7637-3:2016: - capacitive coupling clamp (CCC) method; - direct capacitive coupling (DCC) method; - inductive coupling clamp (ICC) method. ISO 7637-3:2016 applies to road vehicles fitted with nominal 12 V or 24 V electrical systems. For transient pulses immunity, Annex B provides recommended test severity levels in line with the functional performance status classification (FPSC) principle described in ISO 7637‑1.
ISO 7637-3:2016 defines bench test methods to evaluate the immunity of devices under test (DUTs) to transient pulses coupled to lines other than supply lines. The test pulses simulate both fast and slow transient disturbances caused by the switching of inductive loads and relay contact bounce.
The following three test methods are described in ISO 7637-3:2016:
- capacitive coupling clamp (CCC) method;
- direct capacitive coupling (DCC) method;
- inductive coupling clamp (ICC) method.
ISO 7637-3:2016 applies to road vehicles fitted with nominal 12 V or 24 V electrical systems.
For transient pulses immunity, Annex B provides recommended test severity levels in line with the functional performance status classification (FPSC) principle described in ISO 7637‑1.
<p>ISO 7637-3:2007 establishes a bench top test for the evaluation of the immunity of devices under test (DUTs) to transient transmission by coupling via lines other than supply lines. The test transient pulses simulate both fast and slow transient disturbances, such as those caused by the switching of inductive loads and relay contact bounce.</p> <p>Three test methods are described in ISO 7637-3:2007:</p> <ul> <li> the capacitive coupling clamp (CCC) method;</li> <li> the direct capacitive coupling (DCC) method; and</li> <li> the inductive coupling clamp (ICC) method.</li> </ul> <p>Only one test method need be selected for slow transients and only one method need be selected for fast transients.</p> <p>ISO 7637-3:2007 applies to road vehicles fitted with nominal 12 V, 24 V or 42 V electrical systems.</p> <p>For transient immunity, Annex B provides recommended test severity levels in line with the functional performance status classification (FPSC) principle described in ISO 7637-1.</p>
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.
The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ