ISO 7753:2023

ISO 7753:2023

September 2023
International standard Current

Nuclear criticality safety - Use of criticality accident alarm systems for operations

This document provides requirements and guidance regarding the use of CAAS for operations of a nuclear facility. Requirements and guidance on CAAS design are provided in the IEC 60860.This document is applicable to operations with fissile materials outside nuclear reactors but within the boundaries of nuclear establishments.This document applies when a need for CAAS has been established. Information about the need for CAAS is given in Annex C.This document does not include details of administrative steps, which are considered to be activities of a robust management system (ISO 14943 provides details of administrative steps).Details of nuclear accident dosimetry and personnel exposure evaluations are not within the scope of this document.This document is concerned with gamma and neutron radiation rate-sensing systems. Specific detection criteria can also be met with integrating systems; systems detecting either neutron or gamma radiation can also be used. Equivalent considerations then apply.

View the extract
Main informations

Collections

International ISO standards

Thematics

Sécurité, Gestion des risques et SST, QSE

Publication date

September 2023

Number of pages

29 p.

Reference

ISO 7753:2023

ICS Codes

27.120.20   Nuclear power plants. Safety

Print number

1
Sumary
Nuclear criticality safety - Use of criticality accident alarm systems for operations

This document provides requirements and guidance regarding the use of CAAS for operations of a nuclear facility. Requirements and guidance on CAAS design are provided in the IEC 60860.

This document is applicable to operations with fissile materials outside nuclear reactors but within the boundaries of nuclear establishments.

This document applies when a need for CAAS has been established. Information about the need for CAAS is given in Annex C.

This document does not include details of administrative steps, which are considered to be activities of a robust management system (ISO 14943 provides details of administrative steps).

Details of nuclear accident dosimetry and personnel exposure evaluations are not within the scope of this document.

This document is concerned with gamma and neutron radiation rate-sensing systems. Specific detection criteria can also be met with integrating systems; systems detecting either neutron or gamma radiation can also be used. Equivalent considerations then apply.

Replaced standards (1)
ISO 7753:1987
August 1987
International standard Cancelled
Nuclear energy. Performance and testing requirements for criticality detection and alarm systems.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ