NF EN ISO 10052
Acoustics - Field measurements of airborne and impact sound insulation and of service equipment sound - Survey method
This document specifies field survey methods for measuringa) airborne sound insulation between rooms,b) impact sound insulation of floors,c) airborne sound insulation of façades, andd) sound pressure levels in rooms caused by service equipment.The methods described in this document are applicable for measurements in rooms of dwellings or in rooms of comparable size with a maximum of 150 m3.For airborne sound insulation, impact sound insulation and façade sound insulation the method gives values which are (octave band) frequency dependent. They can be converted into a single number characterising the acoustical performances by application of ISO 717-1 and ISO 717-2. For heavy/soft impact sound insulation, the results also are given as A-weighted maximum impact sound pressure level. For service equipment sound the results are given directly in A - or C -weighted sound pressure levels.
This document specifies field survey methods for measuring
a) airborne sound insulation between rooms,
b) impact sound insulation of floors,
c) airborne sound insulation of façades, and
d) sound pressure levels in rooms caused by service equipment.
The methods described in this document are applicable for measurements in rooms of dwellings or in rooms of comparable size with a maximum of 150 m3.
For airborne sound insulation, impact sound insulation and façade sound insulation the method gives values which are (octave band) frequency dependent. They can be converted into a single number characterising the acoustical performances by application of ISO 717-1 and ISO 717-2. For heavy/soft impact sound insulation, the results also are given as A-weighted maximum impact sound pressure level. For service equipment sound the results are given directly in A - or C -weighted sound pressure levels.
ISO 10052:2004 specifies field survey methods for measuring: a) airborne sound insulation between rooms; b) impact sound insulation of floors; c) airborne sound insulation of facades; and d) sound pressure levels in rooms caused by service equipment. The methods described in ISO 10052:2004 are applicable to measurements in rooms of dwellings or in rooms of comparable size with a maximum of 150 m 3 .
Le présent amendement modifie la définition 3.14 et le paragraphe 6.3.3 de la NF EN ISO 10052 de septembre 2005.
- Avant-propos
-
1 Domaine d'application
-
2 Références normatives
-
3 Termes et définitions
-
4 Grandeurs exprimées en valeurs uniques
-
5 Appareillage
-
6 Mode opératoire d'essai et évaluation
-
7 Expression des résultats
-
8 Rapport d'essai
- Annexe B (normative) Conditions et cycles de fonctionnement pour le mesurage du niveau de pression acoustique maximal et du niveau de pression acoustique continu équivalent
- Annexe A (informative) Formulaires pour l'expression des résultats
- Bibliographie
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ