NF EN ISO 10848-1
Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 1 : Frame document
ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one or several building components. These measurements are performed in a laboratory test facility or in the field.The performance of the building components is expressed either as an overall quantity for the combination of elements and junction (such as the normalized flanking level difference and/or normalized flanking impact sound pressure level) or as the vibration reduction index of a junction or the normalized direction-average vibration level difference of a junction.Two approaches are used for structure-borne sound sources in buildings, a normalized flanking equipment sound pressure level and a transmission function that can be used to estimate sound pressure levels in a receiving room due to structure-borne excitation by service equipment in a source room. The former approach assumes that flanking transmission is limited to one junction (or no junction if the element supporting the equipment is the separating element), and the latter considers the combination of direct (if any) and all flanking transmission paths.ISO 10848-1:2017 contains definitions, general requirements for test elements and test rooms, and measurement methods. Guidelines are given for the selection of the quantity to be measured, depending on the junction and the types of building elements involved. Other parts of ISO 10848 specify the application for different types of junction and building elements.The quantities characterizing the flanking transmission can be used to compare different products, or to express a requirement, or as input data for prediction methods, such as ISO 12354‑1 and ISO 12354‑2.
ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one or several building components. These measurements are performed in a laboratory test facility or in the field.
The performance of the building components is expressed either as an overall quantity for the combination of elements and junction (such as the normalized flanking level difference and/or normalized flanking impact sound pressure level) or as the vibration reduction index of a junction or the normalized direction-average vibration level difference of a junction.
Two approaches are used for structure-borne sound sources in buildings, a normalized flanking equipment sound pressure level and a transmission function that can be used to estimate sound pressure levels in a receiving room due to structure-borne excitation by service equipment in a source room. The former approach assumes that flanking transmission is limited to one junction (or no junction if the element supporting the equipment is the separating element), and the latter considers the combination of direct (if any) and all flanking transmission paths.
ISO 10848-1:2017 contains definitions, general requirements for test elements and test rooms, and measurement methods. Guidelines are given for the selection of the quantity to be measured, depending on the junction and the types of building elements involved. Other parts of ISO 10848 specify the application for different types of junction and building elements.
The quantities characterizing the flanking transmission can be used to compare different products, or to express a requirement, or as input data for prediction methods, such as ISO 12354‑1 and ISO 12354‑2.
Le présent document spécifie les méthodes de mesure à utiliser en laboratoire d'essai pour caractériser un ou plusieurs éléments de construction en matière de transmissions latérales. Les performances des éléments de constructions sont exprimées soit par une grandeur globale représentative de l'association des éléments et de la jonction (telle que Dn,f et/ou Ln,f) soit par l'indice d'affaiblissement vibratoire Kij d'une jonction. Le présent document comprend des exigences générales relatives aux échantillons et aux salles d'essai ainsi que les méthodes de mesure. Des lignes directrices sont données pour la sélection de la grandeur à mesurer, en fonction de la jonction et des types d'éléments de construction impliqués.
- Avant-propos
-
1 Domaine d'application
-
2 Références normatives
-
3 Termes et définitions
-
4 Grandeurs permettant de caractériser les transmissions latérales
-
5 Appareillage
-
6 Exigences générales relatives aux installations d'essai et aux éléments soumis à l'essai
-
7 Méthodes de mesure
-
8 Influences des autres parties de l'installation d'essai ou de la structure du bâtiment sur site
-
9 Masquage
-
10 Expression des résultats
- Annexe A (normative) Évaluation de l'atténuation vibratoire avec la distance
- Annexe B (normative) Source sonore solidienne étalonnée
- Bibliographie
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ