NF EN ISO 10848-1

NF EN ISO 10848-1

November 2006
Standard Cancelled

Acoustics - Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms - Part 1 : frame document

ISO 10848-1:2006 contains definitions, general requirements for test specimens and test rooms, and methods for measurement of the flanking transmission. Guidelines are given for the selection of the quantity to be measured depending on the junction and the types of building elements involved.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

November 2006

Number of pages

34 p.

Reference

NF EN ISO 10848-1

ICS Codes

91.120.20   Acoustics in building. Sound insulation

Classification index

S31-097-1

Print number

1 - 27/10/2006

International kinship

European kinship

EN ISO 10848-1:2006
Sumary
Acoustics - Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms - Part 1 : frame document

ISO 10848-1:2006 contains definitions, general requirements for test specimens and test rooms, and methods for measurement of the flanking transmission. Guidelines are given for the selection of the quantity to be measured depending on the junction and the types of building elements involved.

Standard replaced by (1)
NF EN ISO 10848-1
October 2017
Standard Current
Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 1 : Frame document

<p>ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one or several building components. These measurements are performed in a laboratory test facility or in the field.</p> <p>The performance of the building components is expressed either as an overall quantity for the combination of elements and junction (such as the normalized flanking level difference and/or normalized flanking impact sound pressure level) or as the vibration reduction index of a junction or the normalized direction-average vibration level difference of a junction.</p> <p>Two approaches are used for structure-borne sound sources in buildings, a normalized flanking equipment sound pressure level and a transmission function that can be used to estimate sound pressure levels in a receiving room due to structure-borne excitation by service equipment in a source room. The former approach assumes that flanking transmission is limited to one junction (or no junction if the element supporting the equipment is the separating element), and the latter considers the combination of direct (if any) and all flanking transmission paths.</p> <p>ISO 10848-1:2017 contains definitions, general requirements for test elements and test rooms, and measurement methods. Guidelines are given for the selection of the quantity to be measured, depending on the junction and the types of building elements involved. Other parts of ISO 10848 specify the application for different types of junction and building elements.</p> <p>The quantities characterizing the flanking transmission can be used to compare different products, or to express a requirement, or as input data for prediction methods, such as ISO 12354‑1 and ISO 12354‑2.</p>

Table of contents
View the extract
  • Avant-propos
    iv
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Termes et définitions
    2
  • 4 Grandeurs permettant de caractériser les transmissions latérales
    6
  • 4.1 Généralités
    6
  • 4.2 Isolement acoustique latéral normalisé, D,j, et niveau du bruit de choc latéral normalisé, Ln f
    6
  • 4.3 Indice d'affaiblissement vibratoire, Kij
    7
  • 4.4 Choix du principe de mesurage
    8
  • 5 Appareillage de mesure
    10
  • 6 Exigences générales relatives aux échantillons et aux salles d'essai
    10
  • 7 Méthodes de mesure
    11
  • 7.1 Mesurage de Dn,f et de Ln f
    11
  • 7.2 Mesurage de l'indice d'affaiblissement vibratoire avec excitation solidienne
    13
  • 7.3 Mesurage de la durée de réverbération structurale
    16
  • 7.4 Mesurage de l'indice d'affaiblissement vibratoire avec excitation aérienne
    17
  • 7.5 Gamme de fréquences des mesurages
    18
  • 8 Influence des structures de l'installation d'essai
    18
  • 8.1 Critère pour vérifier les transmissions latérales par les constructions de l'installation d'essai
    18
  • 8.2 Limite conventionnelle pour les éléments légers par rapport aux éléments environnants de l'installation d'essai
    19
  • 8.3 Mode opératoire de vérification pour un élément latéral léger, structurellement indépendant d'un élément de séparation
    19
  • 9 Écran de protection acoustique
    19
  • Annexe A (normative) Évaluation de l'indice unique de l'indice d'affaiblissement vibratoire
    25
  • Bibliographie
    26