NF EN ISO 10993-18
NF EN ISO 10993-18

NF EN ISO 10993-18

December 2009
Standard Cancelled

Biological evaluation of medical devices - Part 18: Chemical characterization of materials

Main informations

Collections

National standards and national normative documents

Publication date

December 2009

Number of pages

27 p.

Reference

NF EN ISO 10993-18

ICS Codes

11.040.01   Medical equipment in general
11.100.20   Biological evaluation of medical devices

Print number

1 - décembre 2009

International kinship

ISO 10993-18:2005

European kinship

EN ISO 10993-18:2009
Replaced standards (1)
NF EN ISO 10993-18
NF EN ISO 10993-18
January 2005
Standard Cancelled
Biological evaluation of medical devices — Part 18: Chemical characterization of materials

Standard replaced by (1)
NF EN ISO 10993-18
Standard Current
Biological evaluation of medical devices - Part 18 : chemical characterization of medical device materials within a risk management process

This document specifies a framework for the identification, and if necessary, quantification of constituents of a medical device, allowing the identification of biological hazards and the estimation and control of biological risks from material constituents, using a generally stepwise approach to the chemical characterization which can include one or more of the following: — the identification of its materials of construction (medical device configuration); — the characterization of the materials of construction via the identification and quantification of their chemical constituents (material composition); — the characterization of the medical device for chemical substances that were introduced during manufacturing (e.g. mould release agents, process contaminants, sterilization residues); — the estimation (using laboratory extraction conditions) of the potential of the medical device, or its materials of construction, to release chemical substances under clinical use conditions (extractables); — the measurement of chemical substances released from a medical device under its clinical conditions of use (leachables). This document can also be used for chemical characterization (e.g. the identification and/or quantification) of degradation products. Information on other aspects of degradation assessment are covered in ISO 10993-9, ISO 10993-13, ISO 10993-14 and ISO 10993-15. The ISO 10993 series is applicable when the material or medical device has direct or indirect body contact (see ISO 10993-1 for categorization by nature of body contact). This document is intended for suppliers of materials and manufacturers of medical devices, to support a biological evaluation.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
What is the Redline format?
New: UPSELL service
Need to identify, monitor and decipher standards?