NF EN ISO 11138-5

NF EN ISO 11138-5

October 2006
Standard Cancelled

Sterilization of health care products - Biological indicators - Part 5 : biological indicators for low-temperature steam and formaldehyde sterilization processes

ISO 11138-5:2006 provides specific requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilization processes employing low-temperature steam and formaldehyde as the sterilizing agent.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

October 2006

Number of pages

15 p.

Reference

NF EN ISO 11138-5

ICS Codes

11.080.01   Sterilization and disinfection in general

Classification index

S98-004-5

Print number

1 - 15/09/2006

International kinship

ISO 11138-5:2006

European kinship

EN ISO 11138-5:2006
Sumary
Sterilization of health care products - Biological indicators - Part 5 : biological indicators for low-temperature steam and formaldehyde sterilization processes

ISO 11138-5:2006 provides specific requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilization processes employing low-temperature steam and formaldehyde as the sterilizing agent.

Replaced standards (1)
NF EN 866-5
January 2000
Standard Cancelled
Biological systems for testing sterilizers and sterilization processes - Part 5 : particular systems for use in low temperature steam and formaldehyde sterilizers

Le présent document spécifie les exigences des porte-germes inoculés et des indicateurs biologiques utilisés pour l'évaluation des performances des stérilisateurs à la vapeur d'eau et au formaldéhyde à basse température.

Standard replaced by (1)
NF EN ISO 11138-5
June 2017
Standard Current
Sterilization of health care products - Biological indicators - Part 5 : biological indicators for low-temperature steam and formaldehyde sterilization processes

ISO 11138-5:2017 specifies requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilization processes employing low-temperature steam and formaldehyde as the sterilizing agent. NOTE 1 Requirements for validation and control of low-temperature steam and formaldehyde sterilization processes are provided by ISO 14937. NOTE 2 Requirements for work place safety can be provided by national or regional regulations.

New: UPSELL service
- The UPSELL service allows you to easily update one of your standards.
- With a single click, add a new language, the Requirements or Redline+ service and add one or more additional users.
- Whether you are in the process of acquiring a standard or it is already available in your personal space, the UPSELL service is available at every stage to help you understand it and implement it within your organization.
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ