NF EN ISO 12759-4
Fans - Efficiency classification for fans - Part 4 : driven fans at maximum operating speed
This document establishes a system for the classification of fan efficiency for all fan types driven by motors of nominal rating 0,125 kW and above. It applies to driven fans only, but not to the system (finished original equipment manufacturer's product, for example box fans and roof fans or ventilation system) in which they might be installed. This document describes a number of different procedures to classify the efficiency of a fan or to apply a minimum efficiency limit (MEL). Those procedures are described in: ? ISO 12759-3;? this document (ISO 12759-4);? ISO 12759-5;? ISO 12759-6.There is no method described to compare these classifications and MEL's.
This document establishes a system for the classification of fan efficiency for all fan types driven by motors of nominal rating 0,125 kW and above. It applies to driven fans only, but not to the system (finished original equipment manufacturer's product, for example box fans and roof fans or ventilation system) in which they might be installed. This document describes a number of different procedures to classify the efficiency of a fan or to apply a minimum efficiency limit (MEL). Those procedures are described in:
? ISO 12759-3;
? this document (ISO 12759-4);
? ISO 12759-5;
? ISO 12759-6.
There is no method described to compare these classifications and MEL's.
ISO 12759:2010 specifies requirements for classification of fan efficiency for all fan types driven by motors with an electrical input power range from 0,125 kW to 500 kW. It is applicable to (bare shaft and driven) fans, as well as fans integrated into products. Fans integrated into products are measured as stand-alone fans. It is not applicable to fans for smoke and emergency smoke extraction; fans for industrial processes; fans for automotive application, trains, planes, etc.; fans for potentially explosive atmospheres; box fans, powered roof ventilators and air curtains or jet fans for use in car parks and tunnel ventilation.
-
1 Domaine d'application
-
2 Références normatives
-
3 Termes et définitions
-
4 Symboles et unités
-
5 Informations générales
-
6 Classification
- Annexe A Exemples d'application de lignes de rendement aux ventilateurs entraînés
- Annexe B Facteurs de compensation
- Annexe C Variation de la performance d'un ventilateur en fonction des catégories d'installation
- Annexe D Choix des ventilateurs pour un meilleur rendement
- Annexe E Note explicative
- Bibliographie
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ