NF EN ISO 14630
NF EN ISO 14630

NF EN ISO 14630

December 2024
Standard Current

Non-active surgical implants - General requirements

This document specifies general requirements for non-active surgical implants, hereafter referred to as implants. This document is not applicable to dental implants, dental restorative materials, transendodontic and transradicular implants, intra-ocular lenses and implants utilizing viable animal or human tissue.With regard to safety, this document specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging and information supplied by the manufacturer, and tests to demonstrate compliance with these requirements.Additional requirements applicable to specific implants or implant families are given or referred to in Level 2 and Level 3 standards.NOTE 1        This document does not require that the manufacturer have a quality management system in place. However, many regulatory authorities require the application of a quality management system, such as that described in ISO 13485, to ensure that the implant achieves its intended performance and safety.NOTE 2        In this document, when not otherwise specified, the term "implant" refers to each individual component of a system or a modular implant, provided separately or as a set of components, as well as to all ancillary implants or associated implants designed for improving the intended performance.

Main informations

Collections

National standards and national normative documents

Publication date

December 2024

Number of pages

42 p.

Reference

NF EN ISO 14630

ICS Codes

11.040.40   Implants for surgery, prosthetics and orthotics

Classification index

S94-001

Print number

1

International kinship

ISO 14630:2024

European kinship

EN ISO 14630:2024
Sumary
Non-active surgical implants - General requirements

This document specifies general requirements for non-active surgical implants, hereafter referred to as implants.

This document is not applicable to dental implants, dental restorative materials, transendodontic and transradicular implants, intra-ocular lenses and implants utilizing viable animal or human tissue.

With regard to safety, this document specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging and information supplied by the manufacturer, and tests to demonstrate compliance with these requirements.

Additional requirements applicable to specific implants or implant families are given or referred to in Level 2 and Level 3 standards.

NOTE 1        This document does not require that the manufacturer have a quality management system in place. However, many regulatory authorities require the application of a quality management system, such as that described in ISO 13485, to ensure that the implant achieves its intended performance and safety.

NOTE 2        In this document, when not otherwise specified, the term "implant" refers to each individual component of a system or a modular implant, provided separately or as a set of components, as well as to all ancillary implants or associated implants designed for improving the intended performance.

Replaced standards (1)
NF EN ISO 14630
NF EN ISO 14630
February 2013
Standard Cancelled
Non-active surgical implants - General requirements

ISO 14630:2012 specifies general requirements for non-active surgical implants. ISO 14630:2012 is not applicable to dental implants, dental restorative materials, transendodontic and transradicular implants, intra-ocular lenses and implants utilizing viable animal tissue. With regard to safety, ISO 14630:2012 specifies requirements for intended performance, design attributes, materials, design evaluation, manufacture, sterilization, packaging and information supplied by the manufacturer, and tests to demonstrate compliance with these requirements.

Table of contents
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Performances prévues
  • 5 Caractéristiques de conception
  • 6 Sélection des matériaux
  • 7 Évaluation de la conception
  • 8 Fabrication
  • 9 Stérilisation
  • 10 Emballage
  • 11 Informations fournies par le fabricant
  • ZA Relation entre la présente Norme européenne et les exigences générales en matière de sécurité et de performances concernées du Règlement (UE) 2017/745
  • Bibliographie
ZOOM ON ... the Requirements department

To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:

  • mandatory clauses to satisfy,
  • non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document "ISO/IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents" as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!


What is the Redline format?
New: UPSELL service
Need to identify, monitor and decipher standards?