NF EN ISO 14801
Dentistry - Implants - Dynamic fatigue test for endosseous dental implants
ISO 14801:2007 specifies a method of fatigue testing of single post endosseous dental implants of the transmucosal type and their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes.While it simulates the functional loading of an endosseous dental implant body and its premanufactured prosthetic components under “worst case” conditions, ISO 14801:2007 is not applicable for predicting the in vivo performance of an endosseous dental implant or prosthesis, particularly if multiple endosseous dental implants are used for a prosthesis.
ISO 14801:2007 specifies a method of fatigue testing of single post endosseous dental implants of the transmucosal type and their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes.
While it simulates the functional loading of an endosseous dental implant body and its premanufactured prosthetic components under “worst case” conditions, ISO 14801:2007 is not applicable for predicting the in vivo performance of an endosseous dental implant or prosthesis, particularly if multiple endosseous dental implants are used for a prosthesis.
ISO 14801:2003 specifies a method of fatigue testing of single-post endosseous dental implants of the transmucosal type. It is most useful for comparing endosseous dental implants of different designs or sizes. While it simulates the functional loading of an endosseous dental implant body and its premanufactured prosthetic components under worst-case conditions, ISO 14801:2003 is not applicable for predicting the in vivo performance of an endosseous dental implant or prosthesis, particularly if multiple endosseous dental implants are used for a prosthesis.
ISO 14801:2016 specifies a method of dynamic testing of single post endosseous dental implants of the transmucosal type in combination with their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes. This International Standard is not a test of the fundamental fatigue properties of the materials from which the endosseous implants and prosthetic components are made. This International Standard is not applicable to dental implants with endosseous lengths shorter than 8 mm nor to magnetic attachments. While ISO 14801:2016 simulates the functional loading of an endosseous dental implant under "worst case" conditions, it is not applicable for predicting the in vivo performance of an endosseous dental implant or dental prosthesis, particularly if multiple endosseous dental implants are used for a dental prosthesis.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ