NF EN ISO 1516

NF EN ISO 1516

May 2002
Standard Current

Determination of flash/no flash - Closed cup equilibrium method

This International Standard specifies a method to determine if paints, varnishes, paint binders, solvents, petroleum or related products, when maintained at a selected equilibrium temperature and under the conditions of the test, give off sufficient flammable vapour to cause ignition on application of an external source of flame applied in a standard manner. This International Standard is not applicable to water-borne paints which may, however, be tested using ISO 3680. The method is suitable for use over the temperature range -30 °C to 110 °C, depending on the use of different apparatus listed in Table 1. The interpretation of results obtained from solvent mixtures containing halogenated hydrocarbons, should be considered with caution, as these mixtures can give anomalous results.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

May 2002

Number of pages

19 p.

Reference

NF EN ISO 1516

ICS Codes

75.080   Petroleum products in general
87.040   Paints and varnishes

Classification index

T60-614

Print number

1 - 07/12/2002

International kinship

European kinship

EN ISO 1516:2002
Sumary
Determination of flash/no flash - Closed cup equilibrium method

This International Standard specifies a method to determine if paints, varnishes, paint binders, solvents, petroleum or related products, when maintained at a selected equilibrium temperature and under the conditions of the test, give off sufficient flammable vapour to cause ignition on application of an external source of flame applied in a standard manner.

This International Standard is not applicable to water-borne paints which may, however, be tested using ISO 3680.

The method is suitable for use over the temperature range -30 °C to 110 °C, depending on the use of different apparatus listed in Table 1.

The interpretation of results obtained from solvent mixtures containing halogenated hydrocarbons, should be considered with caution, as these mixtures can give anomalous results.

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Terme et définition
    2
  • 4 Principe
    2
  • 5 Produits
    2
  • 6 Appareillage
    2
  • 7 Préparation de l'appareillage
    3
  • 8 Échantillonnage
    4
  • 9 Manipulation des échantillons
    4
  • 10 Température d'essai
    5
  • 11 Mode opératoire
    5
  • 12 Expression des résultats
    6
  • 13 Fidélité
    6
  • 14 Rapport d'essai
    6
  • Annexe A (informative) Données de fidélité extraites de l'ISO 1523
    8
  • Bibliographie
    9
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ